SERVER LENOVO System x3650 M5 3.5" E5-2630 v4 CHÍNH HÃNG, CHẤT LƯỢNG, GIÁ RẺ TẠI THẾ GIỚI SỐ
- (1) Intel Xeon Processor E5-2630 v4 10C 2.2GHz 25MB Cache 2133MHz 85W
- 16GB TruDDR4 Memory PC4-19200 CL17 2400MHz LP RDIMM
- Hard Drive : None (3.5")
- ServeRAID M1215 SAS/SATA 12 Gbps Controller ( RAID 0, 1, 10 )
- 4x integrated RJ-45 Gigabit Ethernet ports (BCM5719).
- 1x systems management port. UEFI, Integrated Management Module II (IMM2.1)
- 8 x 3.5" hot-swap SAS/SATA drive bays
- Redundant 550 W Power Supply (1/2)
- Rack (2U), Rail Kit
- Warranty: 3 Year Onsite Repair 24x7 4 Hour Response
KEY FEATURES MÁY CHỦSERVER LENOVO System x3650 M5 3.5" E5-2630 v4
Abstract
With the powerful, versatile 2U rack server design, the dual-socket Lenovo System x3650 M5 (E5-2600 v4) server can run even more workloads, 24 x 7, and gain faster business insights. Integrated with Intel Xeon processor E5-2600 v4 product family and industry-leading two-socket storage capacity, the System x3650 M5 delivers exceptional performance. Flexible and scalable internal storage configurations include up to 28x 2.5-inch or 14x 3.5-inch drives with a wide selection of drive sizes and types.
This product guide provides essential pre-sales information to understand the structure of the System x3650 M5 offering, its key features and specifications, components and options, and configuration guidelines.
This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the System x3650 M5 and consider its use in IT solutions.
Notes:
- This Product Guide describes currently available models of the Lenovo System x3650 M5 (Machine Type 8871) with the Intel Xeon processor E5-2600 v4 and E5-2600 v3 product families.
- For withdrawn models of the Lenovo System x3650 M5 (Machine Type 5462) with the Intel Xeon processor E5-2600 v3 product family that are no longer available for ordering, see the following Product Guide: Lenovo System x3650 M5 (Machine Type 5462).
Change History
Changes in the September 14 update:
- Added 2.5-inch and 3.5-inch S4500 Entry 6 Gbps SATA hot-swap SSDs
- Added 2.5-inch and 3.5-inch S4600 Mainstream 6 Gbps SATA hot-swap SSDs
- Added 2.5-inch 2.4 TB 10K 12 Gbps SAS hot-swap HDD
- Added ThinkSystem NE2572 25 Gb Ethernet switch
Introduction
With the powerful, versatile 2U rack server design, the dual-socket Lenovo System x3650 M5 (E5-2600 v4) server (Machine Type 8871) can run even more workloads, 24 x 7, and gain faster business insights. Integrated with Intel Xeon processor E5-2600 v4 product family and industry-leading two-socket storage capacity, the System x3650 M5 delivers exceptional performance. Flexible and scalable internal storage configurations include up to 28x 2.5-inch or 14x 3.5-inch drives with a wide selection of drive sizes and types.
Suggested uses: Database, cloud computing and virtualization, enterprise applications, collaboration/email, business analytics and big data, virtual desktops, and Microsoft RemoteFX applications.
The following figure shows the System x3650 M5.
Figure 1. Lenovo System x3650 M5
Did you know?
The System x3650 M5 incorporates energy-smart features for minimized costs and efficient performance. Dual fan zones support operation in up to 40°C environments. The 80 PLUS Titanium power supply units (PSUs) can deliver 96% efficiency at 50% load.
The System x3650 M5 has outstanding memory performance that is achieved by supporting two-RDIMMs-per-channel configurations at speeds up to 12% faster than the Intel specification, while still maintaining world-class reliability.
The System x3650 M5 integrates leadership security and reliability. System x Trusted Platform Assurance, an exclusive set of System x features and practices, establishes a solid security foundation for your workloads. Enterprise-class data protection is provided with optional self-encrypting drives, and advanced diagnostic tools facilitate reduced downtime and costs.
Key features
The System x3650 M5 is a versatile 2U dual-socket business-critical server that offers improved performance and pay-as-you-grow flexibility along with new features that improve server management capability. This powerful system is designed for your most important business applications and cloud deployments.
Combining balanced performance and flexibility, the System x3650 M5 is a great choice for small and medium businesses up to the large enterprise. It can provide outstanding uptime to keep business-critical applications and cloud deployments running safely. Ease of use and comprehensive systems management tools help make deployment easier. Outstanding reliability, availability, and serviceability (RAS) and high-efficiency design improve your business environment and help save operational costs.
Scalability and performance
The System x3650 M5 offers numerous features to boost performance, improve scalability, and reduce costs:
- Improves productivity by offering superior system performance with the Intel Xeon processor E5-2600 v4 product family with up to 22-core processors, up to 55 MB of L3 cache, up to 2400 MHz memory speeds, and up to 9.6 GT/s QPI interconnect links.
- Support for up to two processors, 44 cores, and 88 threads allows to maximize the concurrent execution of multithreaded applications.
- Intelligent and adaptive system performance with energy efficient Intel Turbo Boost Technology allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
- Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
- Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better utilize the hardware for virtualization workloads.
- Up to 2400 MHz memory speeds with two DIMMs per channel running at 2400 MHz to help maximize system performance.
- Up to 1.5 TB of memory capacity with 64 GB load-reduced DIMMs, or LRDIMMs
- The 12 Gbps SAS internal storage connectivity doubles the data transfer rate compared to 6 Gb SAS solutions to maximize performance of storage I/O-intensive applications.
- Flexible and scalable internal storage configurations provide up to 215 TB of storage capacity with 7.68 TB 2.5-inch solid-state drives (SSDs) in a 2U rack form factor.
- The use of SSDs instead of or along with traditional spinning HDDs can significantly improve I/O performance. An SSD can support a significantly higher number of I/O operations per second (IOPS) than a typical HDD.
- The server has four integrated Gigabit Ethernet ports and optional 10 Gb Ethernet ports with ML2 adapters.
- The server offers up to eight PCI Express (PCIe) 3.0 I/O expansion slots plus one dedicated PCIe 3.0 slot for an internal storage controller in a 2U rack form factor.
- With Intel Integrated I/O Technology, the PCI Express 3.0 controller is integrated into the Intel Xeon processor E5-2600 v4 product family. This helps to dramatically reduce I/O latency and increase overall system performance.
Availability and serviceability
The System x3650 M5 provides many features to simplify serviceability and increase system uptime:
- Tool-less cover removal provides easy access to upgrades and serviceable parts, such as processors, memory DIMMs, and adapter cards.
- The server offers hot-swap drives supporting RAID redundancy for data protection and greater system uptime.
- The server offers redundant hot-swap power supplies and hot-swap redundant fans to provide availability for business-critical applications.
- The new Next Gen light path diagnostics LCD display panel simplifies servicing, speeds up problem resolution, and helps improve system availability.
- Proactive Platform Alerts (including PFA and SMART alerts): Processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs, NVMe SSDs, M.2 storage, flash storage adapters), fans, power supplies, RAID controllers, and server ambient and sub-component temperatures. Alerts can be surfaced through the system IMM to managers such as Lenovo XClarity Administrator, VMware vCenter, and Microsoft System Center. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
- SSDs offer significantly better reliability than traditional mechanical HDDs for greater uptime.
- Built-in Integrated Management Module II (IMM2.1) continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failure, to minimize downtime.
- Built-in diagnostics using Dynamic Systems Analysis (DSA) Preboot speeds up troubleshooting tasks to reduce service time.
Manageability and security
Powerful systems management features simplify local and remote management of the System x3650 M5 and deliver enterprise-class data protection:
- The server includes an Integrated Management Module II (IMM2.1) to monitor server availability and perform remote management.
- An integrated industry-standard Unified Extensible Firmware Interface (UEFI) enables improved setup, configuration, and updates, and simplifies error handling.
- Lenovo XClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
- An integrated Trusted Platform Module (TPM) enables advanced cryptographic functionality such as digital signatures and remote attestation.
- System x Trusted Platform Assurance, an exclusive set of System x security features and practices, establishes a solid security foundation for workloads by delivering firmware that is securely built, tested, digitally signed and verified prior to execution.
- The server offers enterprise-class data protection with optional self-encrypting drives.
- Industry-standard AES NI support offers faster, stronger encryption.
- Intel Execute Disable Bit functionality can help prevent certain classes of malicious buffer overflow attacks when combined with a supporting operating system.
- Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.
Energy efficiency
The System x3650 M5 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:
- Energy-efficient planar components help lower operational costs.
- High-efficiency power supplies with 80 PLUS Platinum and Titanium certifications.
- Intel Intelligent Power Capability powers individual processor elements on and off as needed, to reduce power draw.
- Low-voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally constrained data centers and telecommunication environments.
- Low-voltage 1.2 V DDR4 memory offers energy savings compared to 1.35 V and 1.5 V DDR3 DIMMs.
- The server uses hexagonal ventilation holes, a part of Calibrated Vectored Cooling™ technology. Hexagonal holes can be grouped more densely than round holes, providing more efficient airflow through the system.
- Lenovo XClarity Energy Manager provide advanced data center power notification, analysis, and policy-based management to help achieve lower heat output and reduced cooling needs.
Components and connectors
The following figure shows the front of the System x3650 M5 server with up to 16x 2.5-inch drive bays and the Front IO Cage Entry (default).
Figure 2. Front view of the System x3650 M5: 16x 2.5-inch drive bays; Front IO Cage Entry (default)
The following figure shows the front of the System x3650 M5 server with 8x 2.5-inch SAS/SATA drive bays, up to 8x 2.5-inch PCIe drive bays (optional), and the Front IO Cage Entry (default).
Figure 3. Front view of the System x3650 M5: 8x 2.5-inch SAS/SATA and 8x 2.5-inch PCIe drive bays
The following figure shows the front of the System x3650 M5 server with up to 16x 2.5-inch drive bays and the Front IO Cage Standard (optional).
Figure 4. Front view of the System x3650 M5: 16x 2.5-inch drive bays; Front IO Cage Standard (optional)
The following figure shows the front of the System x3650 M5 server with up to 16x 2.5-inch drive bays and the Front IO Cage Advanced (optional).
Figure 5. Front view of the System x3650 M5: 16x 2.5-inch drive bays; Front IO Cage Advanced (optional)
The following figure shows the front of the System x3650 M5 server with up to 24x 2.5-inch drive bays.
Figure 6. Front view of the System x3650 M5: 24x 2.5-inch drive bays
The following figure shows the front of the System x3650 M5 server with 16x 2.5-inch SAS/SATA and 4x 2.5-inch PCIe drive bays.
Figure 7. Front view of the System x3650 M5: 16x 2.5-inch SAS/SATA and 4x 2.5-inch PCIe drive bays
The following figure shows the front of the System x3650 M5 server with 8x 3.5-inch drive bays.
Figure 8. Front view of the System x3650 M5: 8x 3.5-inch drive bays
The following figure shows the front of the System x3650 M5 server with 12x 3.5-inch drive bays.
Figure 9. Front view of the System x3650 M5: 12x 3.5-inch drive bays
The following figure shows the rear of the System x3650 M5 server.
Figure 10. Rear view of the System x3650 M5
The following figure shows the locations of key components inside the System x3650 M5 server.
Figure 11. Internal view of the System x3650 M5
System specifications
The following table lists the system specifications.
Attribute | Specification |
Form factor | 2U rack-mount (Machine Type 8871) |
Processor | Up to two processors of the Intel Xeon processor E5-2600 v4 product family:
|
Chipset | Intel C612 |
Memory | Up to 24 DIMM sockets (12 DIMMs per processor; four memory channels per processor with three DIMMs per channel). Support for RDIMMs and LRDIMMs. Memory types cannot be intermixed. Memory speed up to 2400 MHz. |
Memory maximums |
|
Memory protection | ECC, Chipkill (for x4-based memory DIMMs), memory mirroring, and memory rank sparing. |
Drive bays | Up to 28 SFF SAS/SATA hot-swap drive bays:
|
Storage capacity |
|
Storage controller |
|
Optical drive bays | One for models with 8x 3.5" or up to 16x 2.5" drive bays (models with 24x 2.5" or 12x 3.5" drive bays do not support an internal optical drive). Support for DVD-ROM or Multiburner. |
Tape drive bays | None. |
Network interfaces |
|
I/O expansion slots | Up to nine slots. Slots 4, 5, and 9 are the fixed slots on the system planar, and the remaining slots depend on the riser cards installed. The slots are as follows:
|
Ports |
|
Cooling | Calibrated Vectored Cooling with up to six redundant hot-swap fans; two fan zones with N+1 fan redundancy.
|
Power supply | Up to two redundant hot-swap 550 W, 750 W, or 900 W (100-240V), or 1500 W (200-240V) High Efficiency Platinum AC power supplies, or 750 W or 1300 W (200-240V) High Efficiency Titanium AC power supplies, or 900 W High Efficiency -48 V DC power supplies. |
Video | Matrox G200eR2 with 16 MB memory integrated into the IMM2.1. Maximum resolution is 1600x1200 at 75 Hz with 16 M colors. |
Hot-swap parts | Hard drives, power supplies, and fans. |
Systems management | UEFI, Integrated Management Module II (IMM2.1) based on Renesas SH7758, Predictive Failure Analysis, light path diagnostics, Automatic Server Restart, ToolsCenter, XClarity Administrator, XClarity Energy Manager. Optional IMM2.1 Advanced Upgrade software feature for remote presence (graphics, keyboard and mouse, virtual media). |
Security features | Power-on password, administrator's password, Trusted Platform Module (TPM) 1.2 or 2.0 (configurable UEFI setting). Optional lockable front bezel. |
Operating systems | Microsoft Windows Server 2008 R2, 2012, 2012 R2, and 2016; Red Hat Enterprise Linux 6 (x64) and 7; SUSE Linux Enterprise Server 11 (x64) and 12; VMware vSphere (ESXi) 5.5, 6.0, and 6.5. |
Warranty | Three-year customer-replaceable unit and onsite limited warranty with 9x5 next business day. |
Service and support | Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for System x hardware and some System x third-party applications. |
Dimensions | Height: 87 mm (3.4 in), width: 434 mm (17.1 in), depth: 755 mm (29.7 in) |
Weight | Minimum configuration: 19 kg (41.8 lb), maximum: 34 kg (74.8 lb) |
Standard models
The following table lists the standard models of the System x3650 M5.
Product availability: Standard models of the x3650 M5 (E5-2600 v4) are not available in North America.
Model number* | Intel Xeon processor** (2 maximum) |
Memory RDIMM# | RAID | Drive bays (std / max) |
Drives | NIC | I/O slots (std / max)§ |
Optical drive§§ | LCD display |
Power supply (std / max)*** |
Models announced March 2016 | ||||||||||
8871A2x | 1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W | 1x 8GB | M1215 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871B2x | 1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W | 1x 8GB | M1215 | 8x 3.5" HS / 10† | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 550W HS / 2 |
8871C2x | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M1215 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871C4x | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M1215 | 8x 3.5" HS / 10† | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 550W HS / 2 |
8871D2x | 1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W | 1x 16GB | M5210 1GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871D4x | 1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W | 1x 16GB | M5210 1GB (F) | 12x 3.5" HS / 16‡ | Open bay | 4x GbE | 3 / 9 | None | None | 1x 750W HS / 2 |
8871F2x | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 1x 16GB | M5210 1GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871F4x | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 1x 16GB | M5210 1GB (F) | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 750W HS / 2 |
8871G2x | 1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W | 1x 16GB | M5210 1GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 750W HS / 2 |
8871N2x | 1x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W | 1x 16GB | M5210 2GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 750W HS / 2 |
8871R2x | 1x E5-2667 v4 8C 3.2GHz 25MB 2400MHz 135W | 1x 16GB | M5210 2GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 900W HS / 2 |
8871J2x | 1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W | 1x 16GB | M5210 2GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871L2x | 1x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871Q2x | 1x E5-2697 v4 18C 2.3GHz 45MB 2400MHz 145W | 1x 16GB | M5210 2GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 900W HS / 2 |
* x in the Model number represents a country-specific letter. Ask a Lenovo representative for specifics.
** Processor details: Processor quantity and model, cores, core speed, cache, memory speed, and thermal design power (TDP).
§ With one processor, only two fixed onboard PCIe slots (Slots 4 and 9) can be used (Slot 5 requires the second processor). An internal storage controller occupies PCIe slot 9.
§§ An optional optical drive requires the ODD Cable (00AL956).
*** The power supplies are 80 PLUS Platinum certified.
# Unless otherwise specified in a footnote, the DIMMs installed are x4 RDIMMs.
^ An optional optical drive requires the Front IO Cage Standard (00YD070) or Advanced (00YD002).
^^ An optional LCD display is included in the Front IO Cage Advanced (00YD002).
† The maximum number of the drive bays (10) includes 8x 3.5" front bays and 2x 3.5" or 2x 2.5" rear bays.
‡ The maximum number of the drive bays (16) includes 12x 3.5" front bays, 2x 3.5" rear bays, and 2x 2.5" rear bays.
The standard models of the System x3650 M5 that are listed in Table 2 are shipped with the following items:
- Rack Installation Guide
- Electronic Publications Flyer
- System x Enterprise Slides Kit
Notes:
- Cable Management Arm (CMA) is not included; see Rack installation for ordering information.
- Power cables are not included; see Power supplies and cables for ordering information.
TopSeller models
The following table lists the TopSeller models of the System x3650 M5.
Model number | Intel Xeon processor*** (2 maximum) |
Memory RDIMM# | RAID / HBA |
Drive bays (std / max) |
Drives | NIC | I/O slots (std / max)§ |
Optical drive§§ | LCD display |
Power supply (std / max)** |
TopSeller - United States, Canada | ||||||||||
8871KAU | 1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W | 1x 16GB | M1215 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871KBU | 1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W | 1x 16GB | M1215 | 8x 3.5" HS / 10† | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 900W HS / 2 |
887110R* | 1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W | 4x 8GB## | N2215 | 14x 3.5" HS / 14 | Open bay | 4x GbE | 6 / 9 | None | None | 2x 900W HS / 2 |
8871KCU | 1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W | 1x 16GB | M1215 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871KDU | 1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W | 1x 16GB | M1215 | 8x 3.5" HS / 10† | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 900W HS / 2 |
887116J | 1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W | 1x 16GB | M5210 2GB (F) | 12x 3.5" HS / 16‡ | Open bay | 4x GbE | 3 / 9 | None | None | 2x 900W HS / 2 |
887116I | 1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W | 1x 16GB | M5210 2GB (F) | 24x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 2x 900W HS / 2 |
8871KEU | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M1215 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871KFU | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M1215 | 8x 3.5" HS / 10† | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 900W HS / 2 |
887116A | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M5210 | 24x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871K8U | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871KGU | 1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871KHU | 1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W | 1x 16GB | M5210 | 8x 3.5" HS / 10† | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 900W HS / 2 |
887116B | 1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W | 1x 16GB | M5210 | 24x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871KQU | 1x E5-2637 v4 4C 3.5GHz 15MB 2400MHz 135W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871KJU | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871KKU | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 1x 16GB | M5210 | 8x 3.5" HS / 10† | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 900W HS / 2 |
8871K4U | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
887116F | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 1x 32GB | M5210 | 24x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871K7U | 2x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 2x 32GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 2x 900W HS / 2 |
887110W* | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 4x 8GB# | N2215 | 14x 3.5" HS / 14 | Open bay | 4x GbE | 6 / 9 | None | None | 2x 900W HS / 2 |
8871KXU | 2x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 4x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 2x 900W HS / 2 |
887110T* | 2x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 8x 16GB | N2215 | 14x 3.5" HS / 14 | Open bay | 4x GbE | 6 / 9 | None | None | 2x 900W HS / 2 |
88711A2~ | 2x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 8x 16GB | N2215 | 14x 3.5" HS / 14 | Open bay | 4x GbE | 5 / 9 | None | None | 2x 1300W HS / 2 |
8871KLU | 1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
887110P | 1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871KVU | 2x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W | 8x 16GB | M5210 | 8x 2.5" HS / 20 | 2x 240GB SSD | 4x GbE | 3 / 9 | Option^ | Option^^ | 2x 900W HS / 2 |
8871KMU | 1x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
887116C | 1x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W | 1x 16GB | M5210 | 24x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871K3U | 2x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W | 2x 32GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 2x 900W HS / 2 |
8871KYU | 2x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W | 4x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 2x 900W HS / 2 |
8871KZU | 2x E5-2660 v4 14C 2.0GHz 35MB 2400MHz 105W | 4x 16GB | M5210 1GB (F) | 12x 3.5" HS / 16‡ | Open bay | 4x GbE | 3 / 9 | None | None | 2x 900W HS / 2 |
8871KRU | 1x E5-2667 v4 8C 3.2GHz 25MB 2400MHz 135W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871KNU | 1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871K5U | 1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
887116G | 1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W | 1x 32GB | M5210 | 24x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871KPU | 1x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
887116D | 1x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W | 1x 16GB | M5210 | 24x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871KUU | 2x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W | 2x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 2x 900W HS / 2 |
8871KWU | 2x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W | 8x 16GB | M5210 | 8x 2.5" HS / 20 | 2x 240GB SSD | 4x GbE | 3 / 9 | Option^ | Option^^ | 2x 900W HS / 2 |
88711A1~ | 2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W | 8x 32GB | N2215 | 8x 2.5" HS / 26 | Open bay | 4x GbE | 5 / 9 | None | None | 2x 1300W HS / 2 |
887110U* | 2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W | 8x 16GB | N2215 | 14x 3.5" HS / 14 | Open bay | 4x GbE | 6 / 9 | None | None | 2x 900W HS / 2 |
88711A3~ | 2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W | 8x 16GB | N2215 | 14x 3.5" HS / 14 | Open bay | 4x GbE | 5 / 9 | None | None | 2x 1300W HS / 2 |
887110V* | 2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W | 8x 32GB | N2215 | 14x 3.5" HS / 14 | Open bay | 4x GbE | 6 / 9 | None | None | 2x 900W HS / 2 |
88711A4~ | 2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W | 8x 32GB | N2215 | 14x 3.5" HS / 14 | Open bay | 4x GbE | 5 / 9 | None | None | 2x 1300W HS / 2 |
887110S* | 2x E5-2695 v4 18C 2.1GHz 45MB 2400MHz 120W | 8x 32GB | N2215 | 24x 2.5" HS / 26 | Open bay | 4x GbE | 6 / 9 | None | None | 2x 900W HS / 2 |
8871KSU | 1x E5-2697 v4 18C 2.3GHz 45MB 2400MHz 145W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871K6U | 1x E5-2697 v4 18C 2.3GHz 45MB 2400MHz 145W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
887116H | 1x E5-2697 v4 18C 2.3GHz 45MB 2400MHz 145W | 1x 32GB | M5210 | 24x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871KTU | 1x E5-2699 v4 22C 2.2GHz 55MB 2400MHz 145W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
TopSeller - Europe, Middle East and Africa | ||||||||||
8871EBG | 1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W | 1x 8GB | M1215 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871ECG | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M1215 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871EEG | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871EFG | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | 2x 10K 300GB | 4x GbE | 3 / 9 | Option^ | Option^^ | 2x 550W HS / 2 |
8871EJG | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 750W HS / 2 |
8871ENG | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871EWG | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 750W HS / 2 |
8871EAG | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M5210 | 8x 3.5" HS / 10† | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 750W HS / 2 |
887116L | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M5210 2GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 750W HS / 2 |
8871EDG | 1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W | 1x 16GB | M1215 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871E6G | 1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871EGG | 1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871EKG | 1x E5-2630 v4 10C 2.2GHz 25MB 2133MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 750W HS / 2 |
8871EYG | 1x E5-2637 v4 4C 3.5GHz 15MB 2400MHz 135W | 1x 16GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 1500W HS / 2 |
8871EHG | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871ELG | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 750W HS / 2 |
8871EPG | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871EXG | 1x E5-2640 v4 10C 2.4GHz 25MB 2133MHz 90W | 1x 16GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871E5G | 1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 550W HS / 2 |
8871EMG | 1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 750W HS / 2 |
8871EQG | 1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871SCG | 1x E5-2650 v4 12C 2.2GHz 30MB 2400MHz 105W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871SDG | 1x E5-2667 v4 8C 3.2GHz 25MB 2400MHz 135W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871ERG | 1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 750W HS / 2 |
8871ETG | 1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871SAG | 1x E5-2680 v4 14C 2.4GHz 35MB 2400MHz 120W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871ESG | 1x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 750W HS / 2 |
8871EUG | 1x E5-2690 v4 14C 2.6GHz 35MB 2400MHz 135W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
8871SBG | 1x E5-2697 v4 18C 2.3GHz 45MB 2400MHz 145W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871SEG | 1x E5-2698 v4 20C 2.2GHz 50MB 2400MHz 135W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
8871EVG | 1x E5-2699 v4 22C 2.2GHz 55MB 2400MHz 145W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 1500W HS / 2 |
8871SFG | 1x E5-2699 v4 22C 2.2GHz 55MB 2400MHz 145W | 1x 32GB | M5210 | 8x 2.5" HS / 28 | Open bay | 4x GbE | 3 / 9 | None | None | 1x 900W HS / 2 |
TopSeller - Japan | ||||||||||
8871E7J | 1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W | 1x 8GB | M1215 | 8x 3.5" HS / 10† | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 550W HS / 2 |
8871E2J | 1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W | 1x 8GB | M5210 1GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 550W HS / 2 |
8871E3J | 1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W | 1x 8GB | M5210 1GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 550W HS / 2 |
8871E4J | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 8GB | M5210 1GB (F) | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 550W HS / 2 |
TopSeller - Australia and New Zealand | ||||||||||
887110X | 1x E5-2603 v4 6C 1.7GHz 15MB 1866MHz 85W | 1x 8GB | M1215 | 8x 3.5" HS / 10† | Open bay | 4x GbE | 3 / 9 | Option | Included | 1x 550W HS / 2 |
887110Z | 1x E5-2609 v4 8C 1.7GHz 20MB 1866MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 750W HS / 2 |
88711A0 | 1x E5-2620 v4 8C 2.1GHz 20MB 2133MHz 85W | 1x 16GB | M5210 | 8x 2.5" HS / 20 | Open bay | 4x GbE | 3 / 9 | Option^ | Option^^ | 1x 900W HS / 2 |
*** Processor details: Processor quantity and model, cores, core speed, cache, memory speed, and thermal design power (TDP).
§ With one processor, only two fixed onboard PCIe slots (Slots 4 and 9) can be used (Slot 5 requires the second processor). An internal storage controller occupies PCIe slot 9.
§§ An optional optical drive requires the ODD Cable (00AL956).
** The power supplies are 80 PLUS Platinum certified.
† The maximum number of the drive bays (10) includes 8x 3.5" front bays and 2x 2.5" rear bays.
‡ The maximum number of the drive bays (16) includes 12x 3.5" front bays, 2x 3.5" rear bays, and 2x 2.5" rear bays.
* This model includes the SD Media Adapter with two blank SD cards (00ML706), PCIe Riser 1 (2 x8 FH/FL + 1 x8 FH/HL Slots) (00KA498), and IMM Advanced Upgrade (90Y3901).
# Unless otherwise specified in a footnote, the DIMMs installed are x4 RDIMMs.
## 8 GB 2Rx8 memory RDIMM (46W0825)
^ An optional optical drive requires the Front IO Cage Standard (00YD070) or Advanced (00YD002).
^^ An optional LCD display is included in the optional Front IO Cage Advanced (00YD002).
~ This model includes the dual-rotor fan base, SD Media Adapter with two blank SD cards (00ML706), PCIe Riser 1 (1 x16 FH/FL + 1 x8 FH/HL Slots) (00KA489), and IMM Advanced Upgrade (90Y3901).
The TopSeller models of the System x3650 M5 listed in this section are shipped with the following items:
- Rack Installation Guide
- Electronic Publications Flyer
- System x Enterprise Slides Kit
- One or two 2.8 m IEC 320-C13 to C14 rack power cords (matches the quantity of power supplies)
Note: Cable Management Arm (CMA) is not included; see Rack installation for ordering information.
Processors
The System x3650 M5 supports up to two processors of the Intel Xeon processor E5-2600 v4 product family. Also, support for the Intel Xeon processor E5-2600 v3 product family is available via CTO only. The following tables list the specifications of the processors for the System x3650 M5.
Processor model | Core frequency (Base / TB Max) | Number of cores / threads | Cache | Max DDR4 frequency | QPI speed | TDP | HT | TB | VT-x | VT-d |
---|---|---|---|---|---|---|---|---|---|---|
E5-2603 v4 | 1.7 GHz | 6 / 6 | 15 MB | 1866 MHz | 6.4 GT/s | 85 W | No | No | Yes | Yes |
E5-2608L v4 | 1.6 GHz | 8 / 16 | 20 MB | 1866 MHz | 6.4 GT/s | 50 W | Yes | No | Yes | Yes |
E5-2609 v4 | 1.7 GHz | 8 / 8 | 20 MB | 1866 MHz | 6.4 GT/s | 85 W | No | No | Yes | Yes |
E5-2618L v4 | 2.2 / 3.2 GHz | 10 / 20 | 25 MB | 2133 MHz | 8.0 GT/s | 75 W | Yes | Yes | Yes | Yes |
E5-2620 v4 | 2.1 / 3 GHz | 8 / 16 | 20 MB | 2133 MHz | 8.0 GT/s | 85 W | Yes | Yes | Yes | Yes |
E5-2623 v4 | 2.6 / 3.2 GHz | 4 / 8 | 10 MB | 2133 MHz | 8.0 GT/s | 85 W | Yes | Yes | Yes | Yes |
E5-2628L v4 | 1.9 / 2.4 GHz | 12 / 24 | 30 MB | 2133 MHz | 8.0 GT/s | 75 W | Yes | Yes | Yes | Yes |
E5-2630 v4 | 2.2 / 3.1 GHz | 10 / 20 | 25 MB | 2133 MHz | 8.0 GT/s | 85 W | Yes | Yes | Yes | Yes |
E5-2630L v4 | 1.8 / 2.9 GHz | 10 / 20 | 25 MB | 2133 MHz | 8.0 GT/s | 55 W | Yes | Yes | Yes | Yes |
E5-2637 v4 | 3.5 / 3.7 GHz | 4 / 8 | 15 MB | 2400 MHz | 9.6 GT/s | 135 W | Yes | Yes | Yes | Yes |
E5-2640 v4 | 2.4 / 3.4 GHz | 10 / 20 | 25 MB | 2133 MHz | 8.0 GT/s | 90 W | Yes | Yes | Yes | Yes |
E5-2643 v4 | 3.4 / 3.7 GHz | 6 / 12 | 20 MB | 2400 MHz | 9.6 GT/s | 135 W | Yes | Yes | Yes | Yes |
E5-2648L v4 | 1.8 / 2.5 GHz | 14 / 28 | 35 MB | 2400 MHz | 9.6 GT/s | 75 W | Yes | Yes | Yes | Yes |
E5-2650 v4 | 2.2 / 2.9 GHz | 12 / 24 | 30 MB | 2400 MHz | 9.6 GT/s | 105 W | Yes | Yes | Yes | Yes |
E5-2650L v4 | 1.7 / 2.5 GHz | 14 / 28 | 35 MB | 2400 MHz | 9.6 GT/s | 65 W | Yes | Yes | Yes | Yes |
E5-2658 v4 | 2.3 / 2.8 GHz | 14 / 28 | 35 MB | 2400 MHz | 9.6 GT/s | 105 W | Yes | Yes | Yes | Yes |
E5-2660 v4 | 2 / 3.2 GHz | 14 / 28 | 35 MB | 2400 MHz | 9.6 GT/s | 105 W | Yes | Yes | Yes | Yes |
E5-2667 v4 | 3.2 / 3.6 GHz | 8 / 16 | 25 MB | 2400 MHz | 9.6 GT/s | 135 W | Yes | Yes | Yes | Yes |
E5-2680 v4 | 2.4 / 3.3 GHz | 14 / 28 | 35 MB | 2400 MHz | 9.6 GT/s | 120 W | Yes | Yes | Yes | Yes |
E5-2683 v4 | 2.1 / 3 GHz | 16 / 32 | 40 MB | 2400 MHz | 9.6 GT/s | 120 W | Yes | Yes | Yes | Yes |
E5-2690 v4 | 2.6 / 3.5 GHz | 14 / 28 | 35 MB | 2400 MHz | 9.6 GT/s | 135 W | Yes | Yes | Yes | Yes |
E5-2695 v4 | 2.1 / 3.3 GHz | 18 / 36 | 45 MB | 2400 MHz | 9.6 GT/s | 120 W | Yes | Yes | Yes | Yes |
E5-2697 v4 | 2.3 / 3.6 GHz | 18 / 36 | 45 MB | 2400 MHz | 9.6 GT/s | 145 W | Yes | Yes | Yes | Yes |
E5-2697A v4 | 2.6 / 3.6 GHz | 16 / 32 | 40 MB | 2400 MHz | 9.6 GT/s | 145 W | Yes | Yes | Yes | Yes |
E5-2698 v4 | 2.2 / 3.6 GHz | 20 / 40 | 50 MB | 2400 MHz | 9.6 GT/s | 135 W | Yes | Yes | Yes | Yes |
E5-2699 v4 | 2.2 / 3.6 GHz | 22 / 44 | 55 MB | 2400 MHz | 9.6 GT/s | 145 W | Yes | Yes | Yes | Yes |
E5-2699R v4 | 2.2 / 3.6 GHz | 22 / 44 | 55 MB | 2400 MHz | 9.6 GT/s | 145 W | Yes | Yes | Yes | Yes |
E5-2699A v4 | 2.4 / 3.6 GHz | 22 / 44 | 55 MB | 2400 MHz | 9.6 GT/s | 145 W | Yes | Yes | Yes | Yes |
Processor model | Core frequency (Base / TB Max) | Number of cores / threads | Cache | Max DDR4 frequency | QPI speed | TDP | HT | TB | VT-x | VT-d |
---|---|---|---|---|---|---|---|---|---|---|
E5-2603 v3 | 1.6 GHz | 6 / 6 | 15 MB | 1600 MHz | 6.4 GT/s | 85 W | No | No | Yes | Yes |
E5-2609 v3 | 1.9 GHz | 6 / 6 | 15 MB | 1600 MHz | 6.4 GT/s | 85 W | No | No | Yes | Yes |
E5-2620 v3 | 2.4 / 3.2 GHz | 6 / 12 | 15 MB | 1866 MHz | 8 GT/s | 85 W | Yes | Yes | Yes | Yes |
E5-2630 v3 | 2.4 / 3.2 GHz | 8 / 16 | 20 MB | 1866 MHz | 8 GT/s | 85 W | Yes | Yes | Yes | Yes |
E5-2640 v3 | 2.6 / 3.4 GHz | 8 / 16 | 20 MB | 1866 MHz | 8 GT/s | 90 W | Yes | Yes | Yes | Yes |
E5-2650 v3 | 2.3 / 3 GHz | 10 / 20 | 25 MB | 2133 MHz | 9.6 GT/s | 105 W | Yes | Yes | Yes | Yes |
E5-2660 v3 | 2.6 / 3.3 GHz | 10 / 20 | 25 MB | 2133 MHz | 9.6 GT/s | 105 W | Yes | Yes | Yes | Yes |
E5-2670 v3 | 2.3 / 3.1 GHz | 12 / 24 | 30 MB | 2133 MHz | 9.6 GT/s | 120 W | Yes | Yes | Yes | Yes |
E5-2680 v3 | 2.5 / 3.3 GHz | 12 / 24 | 30 MB | 2133 MHz | 9.6 GT/s | 120 W | Yes | Yes | Yes | Yes |
E5-2690 v3 | 2.6 / 3.5 GHz | 12 / 24 | 30 MB | 2133 MHz | 9.6 GT/s | 135 W | Yes | Yes | Yes | Yes |
E5-2695 v3 | 2.3 / 3.3 GHz | 14 / 28 | 35 MB | 2133 MHz | 9.6 GT/s | 120 W | Yes | Yes | Yes | Yes |
E5-2697 v3 | 2.6 / 3.6 GHz | 14 / 28 | 35 MB | 2133 MHz | 9.6 GT/s | 145 W | Yes | Yes | Yes | Yes |
For System x3650 M5 server models that come standard with one processor, the second processor can be ordered, if required (see the following table for ordering information). The second processor must be of the same model as the first processor. The second processor option includes two system fans.
Description | Part number | Feature codes* |
---|---|---|
Intel Xeon Processor E5-2600 v4 product family | ||
Intel Xeon Processor E5-2603 v4 6C 1.7GHz 15MB Cache 1866MHz 85W | 00YJ203 | ATEU / ATFK |
Intel Xeon Processor E5-2608L v4 8C 1.6GHz 20MB Cache 1866MHz 50W | 00YJ219 | ATFA / ATG1 |
Intel Xeon Processor E5-2609 v4 8C 1.7GHz 20MB Cache 1866MHz 85W | 00YJ196 | ATEM / ATFC |
Intel Xeon Processor E5-2618L v4 10C 2.2GHz 25MB Cache 2133MHz 75W | 00YJ218 | ATF9 / ATG0 |
Intel Xeon Processor E5-2620 v4 8C 2.1GHz 20MB Cache 2133MHz 85W | 00YJ195 | ATEL / ATFB |
Intel Xeon Processor E5-2623 v4 4C 2.6GHz 10MB Cache 2133MHz 85W | 00YJ217 | ATF8 / ATFZ |
Intel Xeon Processor E5-2628L v4 12C 1.9GHz 30MB Cache 2133MHz 75W | 00YJ215 | ATF6 / ATFX |
Intel Xeon Processor E5-2630 v4 10C 2.2GHz 25MB Cache 2133MHz 85W | 00YJ198 | ATEP / ATFE |
Intel Xeon Processor E5-2630L v4 10C 1.8GHz 25MB Cache 2133MHz 55W | 00YJ209 | ATF0 / ATFR |
Intel Xeon Processor E5-2637 v4 4C 3.5GHz 15MB Cache 2400MHz 135W | 00YJ208 | ATEZ / ATFQ |
Intel Xeon Processor E5-2640 v4 10C 2.4GHz 25MB Cache 2133MHz 90W | 00YJ199 | ATEQ / ATFF |
Intel Xeon Processor E5-2643 v4 6C 3.4GHz 20MB Cache 2400MHz 135W | 00YJ207 | ATEY / ATFP |
Intel Xeon Processor E5-2648L v4 14C 1.8GHz 35MB Cache 2400MHz 75W | 00YJ213 | ATF4 / ATFV |
Intel Xeon Processor E5-2650 v4 12C 2.2GHz 30MB Cache 2400MHz 105W | 00YJ197 | ATEN / ATFD |
Intel Xeon Processor E5-2650L v4 14C 1.7GHz 35MB Cache 2400MHz 65W | 00YJ210 | ATF1 / ATFS |
Intel Xeon Processor E5-2658 v4 14C 2.3GHz 35MB Cache 2400MHz 105W | 00YJ214 | ATF5 / ATFW |
Intel Xeon Processor E5-2660 v4 14C 2.0GHz 35MB Cache 2400MHz 105W | 00YJ205 | ATEW / ATFM |
Intel Xeon Processor E5-2667 v4 8C 3.2GHz 25MB Cache 2400MHz 135W | 00YJ201 | ATES / ATFH |
Intel Xeon Processor E5-2680 v4 14C 2.4GHz 35MB Cache 2400MHz 120W | 00YJ202 | ATET / ATFJ |
Intel Xeon Processor E5-2683 v4 16C 2.1GHz 40MB Cache 2400MHz 120W | 00YJ216 | ATF7 / ATFY |
Intel Xeon Processor E5-2690 v4 14C 2.6GHz 35MB Cache 2400MHz 135W | 00YJ200 | ATER / ATFG |
Intel Xeon Processor E5-2695 v4 18C 2.1GHz 45MB Cache 2400MHz 120W | 00YJ206 | ATEX / ATFN |
Intel Xeon Processor E5-2697 v4 18C 2.3GHz 45MB Cache 2400MHz 145W | 00YJ204 | ATEV / ATFL |
Intel Xeon Processor E5-2697A v4 16C 2.6GHz 40MB Cache 2400MHz 145W | 01GT188 | AUDY / AUE0 |
Intel Xeon Processor E5-2698 v4 20C 2.2GHz 50MB Cache 2400MHz 135W | 00YJ212 | ATF3 / ATFU |
Intel Xeon Processor E5-2699 v4 22C 2.2GHz 55MB Cache 2400MHz 145W | 00YJ211 | ATF2 / ATFT |
Intel Xeon Processor E5-2699R v4 22C 2.2GHz 55MB Cache 2400MHz 145W | 01GV376 | AVHA / AVHJ |
Intel Xeon Processor E5-2699A v4 22C 2.4GHz 55MB Cache 2400MHz 145W | 01GV377 | AVHB / AVHK |
Intel Xeon Processor E5-2600 v3 product family | ||
Intel Xeon Processor E5-2603 v3 6C 1.6GHz 15MB 1600MHz 85W | 00FK640 | A5EB / A5EG |
Intel Xeon Processor E5-2609 v3 6C 1.9GHz 15MB 1600MHz 85W | 00FK641 | A5EC / A5EH |
Intel Xeon Processor E5-2620 v3 6C 2.4GHz 15MB 1866MHz 85W | 00FK642 | A5ED / A5EJ |
Intel Xeon Processor E5-2630 v3 8C 2.4GHz 20MB 1866MHz 85W | 00FK643 | A5EE / A5EK |
Intel Xeon Processor E5-2640 v3 8C 2.6GHz 20MB 1866MHz 90W | 00FK644 | A5GT / A5EL |
Intel Xeon Processor E5-2650 v3 10C 2.3GHz 25MB 2133MHz 105W | 00FK645 | A5GU / A5EM |
Intel Xeon Processor E5-2660 v3 10C 2.6GHz 25MB 2133MHz 105W | 00KG839 | ASDA / ASDM |
Intel Xeon Processor E5-2670 v3 12C 2.3GHz 30MB 2133MHz 120W | 00FK647 | A5GV / A5EN |
Intel Xeon Processor E5-2680 v3 12C 2.5GHz 30MB 2133MHz 120W | 00FK648 | A5GW / A5EP |
Intel Xeon Processor E5-2690 v3 12C 2.6GHz 30MB 2133MHz 135W | 00FK649 | A5GX / A5EQ |
Intel Xeon Processor E5-2697 v3 14C 2.6GHz 35MB 2133MHz 145W | 00KG843 | ASDE / ASDR |
* The first feature code is for the first processor; the second feature code is for the second processor.
Memory
The System x3650 M5 supports TruDDR4 memory. TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict requirements is selected. It is compatibility tested and tuned on every System x server to maximize performance and reliability.
TruDDR4 memory has a unique signature programmed into the DIMM, which enables System x servers to verify whether the memory installed is qualified and supported. Because TruDDR4 memory is authenticated, certain extended memory performance features can be enabled to extend performance over industry standards. From a service and support standpoint, System x memory automatically assumes the system's warranty, and service and support provided worldwide.
The System x3650 M5 supports up to 12 DIMMs with one processor and up to 24 DIMMs when two processors are installed. Each processor has four memory channels, and there are three DIMMs per channel.
The following rules apply when selecting the memory configuration:
- The server supports RDIMMs and LRDIMMs.
- Mixing different types of memory (RDIMMs and LRDIMMs) is not supported.
- All DIMMs in the server operate at the same speed, which is determined as the lowest value of:
- Memory speed that is supported by the specific processor.
- Memory speed for selected quantity of DIMMs per channel.
The following memory protection technologies are supported:
- ECC
- Chipkill (for x4-based memory DIMMs)
- Memory mirroring
- Memory rank sparing
Chipkill works only in independent channel mode (the default operational mode) and supports only x4-based memory DIMMs.
If memory mirroring is used, then DIMMs must be installed in pairs (a minimum of one pair per each processor), and both DIMMs in a pair must be identical in type and size.
If memory rank sparing is used, then a minimum of one quad-rank DIMM or two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need being identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The size of a rank varies depending on the DIMMs installed.
Chipkill, memory mirroring, and memory rank sparing modes are mutually exclusive. Only one operational memory mode can be enabled on a server, and it is a system-wide setting.
System x engineering tested and validated system designs that support memory speeds beyond Intel memory specifications, which provides benefits for workloads that require memory speed and density. System x TruDDR4 memory is fully supported up to the rated speeds that are shown in the following table. Table cells highlighted with a gray background indicate when the DIMMs are allowed to operate at a higher speed than Intel specifications define.
DIMMs per channel |
RDIMM
|
LR-DIMM
|
||
Memory bus speed | Maximum capacity* | Memory bus speed | Maximum capacity* | |
Intel Xeon processor E5-2600 v4 product family | ||||
1 DPC | 2400 MHz | 256 GB (8x 32 GB) | 2400 MHz | 512 GB (8x 64 GB) |
2 DPC | 2400 MHz | 512 GB (16x 32 GB) | 2400 MHz | 1,024 GB (16x 64 GB) |
3 DPC | 1866 MHz | 768 GB (24x 32 GB) | 2133 MHz | 1,536 GB (24x 64 GB) |
Intel Xeon processor E5-2600 v3 product family | ||||
1 DPC | 2133 MHz | 256 GB (8x 32 GB) | 2133 MHz | 512 GB (8x 64 GB) |
2 DPC | 2133 MHz | 512 GB (16x 32 GB) | 2133 MHz | 1,024 GB (16x 64 GB) |
3 DPC | 1866 MHz | 768 GB (24x 32 GB) | 1866 MHz | 1,536 GB (24x 64 GB) |
* Maximum memory capacity is achieved with two processors installed. With one processor, the capacity is a half of what is shown.
The following table lists memory options available for the System x3650 M5 server.
Description | Part number | Feature code | Maximum supported* |
RDIMMs - 2400 MHz | |||
8GB TruDDR4 Memory (1Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM | 46W0821 | ATC8 | 12 / 24 |
8GB TruDDR4 Memory (2Rx8, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM | 46W0825 | ATC9 | 12 / 24 |
16GB TruDDR4 Memory (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM | 46W0829 | ATCA | 12 / 24 |
16GB TruDDR4 Memory (2Rx8, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM | 01KN301 | AVP0 | 12 / 24** |
32GB TruDDR4 Memory (2Rx4, 1.2V) PC4-19200 CL17 2400MHz LP RDIMM | 46W0833 | ATCB | 12 / 24 |
LRDIMMs - 2400 MHz | |||
64GB TruDDR4 Memory (4Rx4, 1.2V) PC4-19200 PC4 2400MHz LP LRDIMM | 46W0841 | ATGG | 12 / 24 |
* One processor / two processors.
** Not supported with the Intel Xeon processor E5-2600 v3 product family.
Internal storage
The System x3650 M5 server supports the following drive bay configurations:
- Models with 8x 2.5-inch SAS/SATA hot-swap drive bays that can be upgraded to the following drive bay configurations:
- 8x 2.5-inch (front) + 2x 2.5-inch (rear) SAS/SATA hot-swap + 4x 2.5-inch PCIe SSD (front) hot-swap drive bays
- 8x 2.5-inch SAS/SATA (front) + 8x 2.5-inch PCIe SSD (front) hot-swap drive bays
- 16x 2.5-inch SAS/SATA (front) + 4x 2.5-inch PCIe SSD (front) hot-swap drive bays
- 16x 2.5-inch (front) + 2x 2.5-inch (rear) + 2x 2.5-inch (rear) SAS/SATA hot-swap drive bays
- Storage dense models with 8x 2.5-inch SAS/SATA hot-swap drive bays that can be upgraded to up to 28x (up to 24 on the front; up to 4 on the rear) 2.5-inch SAS/SATA hot-swap drive bays
- Models with 8x 3.5-inch SAS/SATA hot-swap drive bays that can be upgraded to the following drive bay configurations (for a total of 10 drive bays):
- 8x 3.5-inch (front) + 2x 3.5-inch (rear) SAS/SATA hot-swap drive bays
- 8x 3.5-inch (front) + 2x 2.5-inch (rear) SAS/SATA hot-swap drive bays
- Models with 12x 3.5-inch SAS/SATA hot-swap drive bays that can be upgraded to up to 16x SAS/SATA hot-swap drive bays: 12x 3.5-inch (front) + 2x 3.5-inch (rear) + 2x 2.5-inch (rear)
The following figure shows the SAS/SATA drive bay configurations.
Figure 12. Internal SAS/SATA drive bay configurations
The following figure shows the SAS/SATA and PCIe drive bay configurations.
Figure 13. Internal SAS/SATA and PCIe drive bay configurations
8x 3.5-inch drive bay models of the System x3650 M5 have one optical disk drive (ODD) bay. For models with up to 16x 2.5-inch drive bays, the optional Front IO Cage Standard or Advanced provides one optical drive bay and 3x USB 2.0 ports. In addition, the Front IO Cage Advanced provides an LCD display. These options are listed in the following table.
Description | Part number | Feature code | Maximum supported |
x3650 M5 Front IO Cage Entry (1x USB only) | None* | ATE5 | 1 |
x3650 M5 Front IO Cage Std. (3x USB, Optional LCD/Optical drive) | 00YD070 | ATE6 | 1 |
x3650 M5 Front IO Cage Adv. (3x USB, LCD, Optional Optical Drive) | 00YD002** | None** | 1 |
* Included with select standard and TopSeller models or configurable via CTO.
** The Front IO Cage Advanced part number (00YD002) includes the Front IO Cage Standard (feature code ATE6), System x3650 M5 2.5" Bezel with LCD Light Path (feature code ATE8), and LCD display (feature code A4VH). If configured via CTO, the LCD display (feature code A4VH) is derived when the Front IO Cage Standard (feature code ATE6) and System x3650 M5 2.5" Bezel with LCD Light Path (feature code ATE8) are selected.
The following table shows the internal storage options available for the System x3650 M5 server.
Description | Part number | Feature code | Maximum supported |
Base drive kits (factory installed)* | |||
System x3650 M5 8x 2.5" HS HDD Assembly Kit (Single RAID) | None* | A5G6 | 1 |
System x3650 M5 16x 2.5" HS HDD Assembly Kit (Single RAID) | None* | A5GF | 1 |
System x3650 M5 16x 2.5" HS HDD Assembly Kit (Dual RAID) | None* | A5GG | 1 |
System x3650 M5 24x 2.5" HS HDD Assembly Kit (Single RAID) | None* | A5G7 | 1 |
System x3650 M5 24x 2.5" HS HDD Assembly Kit (Dual RAID) | None* | A5TN | 1 |
System x3650 M5 24x 2.5" HS HDD Assembly Kit (Triple RAID) | None* | A5G8 | 1 |
System x3650 M5 8x 3.5" HS HDD Assembly Kit | None* | ATEG | 1 |
System x3650 M5 12x 3.5" HS HDD Assembly Kit | None* | A5GE | 1 |
System x3650 M5 Rear 2x 2.5" HDD Kit (Independent RAID) | None* | A5GH | 2 |
System x3650 M5 Rear 2x 3.5" HDD Kit (Cascaded)** | None* | A5GL | 1 |
System x3650 M5 Rear 2x 3.5" HDD Kit (Independent RAID) | None* | A5GK | 1 |
System x3650 M5 Plus 4x 2.5" NVMe PCIe SSD Upgrade Kit | None* | ASRL | 2 |
Upgrade drive kits (require the base drive kit) | |||
System x3650 M5 Plus 8x 2.5" HS HDD Assembly Kit with Expander | 00FK661 | AS44 | 2 |
System x3650 M5 Plus 8x 2.5" HS HDD Assembly Kit | 00FK676 | AS45 | 2 |
System x3650 M5 Rear 2x 2.5" HDD Kit | 00FK658 | AS42 | 2 |
System x3650 M5 Rear 2x 3.5" HDD Kit | 00FK659 | AS43 | 1 |
System x3650 M5 Plus 4x 2.5" NVMe PCIe SSD Upgrade Kit | 00FK677 | None*** | 2 |
* Base drive kits are always factory-installed in either standard or custom (CTO or Special Bid) models, and they might not have an option part number assigned.
** The 2x 3.5-inch Rear HDD Kit is connected to the SAS expander on the 12-drive backplane, that is, to the same storage controller as 12 drive bays on the front.
*** This Upgrade kit can be installed as a field upgrade only, and it includes 1x NVMe PCIe SSD Upgrade Kit (feature code ASRL) and 2x PCIe SSD Extender Adapters (feature code AS95).
The following table lists possible factory-installed internal storage configurations and field upgrades.
Drive bay configuration | Storage controller* | Drive kits required |
---|---|---|
Front drive bays | ||
8x 2.5-in. SAS/SATA hot-swap (front) |
1x RAID or HBA (8 drives) |
Factory installed:
|
16x 2.5-in. SAS/SATA hot-swap (front) |
1x RAID or HBA (16 drives) |
Factory installed:
|
2x RAID or HBA (8+8 drives) |
Factory installed:
|
|
24x 2.5-in. SAS/SATA hot-swap (front) |
1x RAID or HBA (24 drives) |
Factory installed:
|
2x RAID or HBA (16+8 drives) |
Factory installed:
|
|
3x RAID or HBA (8+8+8 drives) |
Factory installed:
|
|
4x 2.5-in. PCIe SSD hot-swap (front) |
2x PCIe Extenders# (2+2) |
Factory installed:
|
8x 2.5-in. PCIe SSD hot-swap (front) |
4x PCIe Extenders# (2+2+2+2) |
Factory installed:
|
8x 3.5-in. SAS/SATA hot-swap (front) |
1x RAID or HBA (8 drives) |
Factory installed:
|
12x 3.5-in. SAS/SATA hot-swap (front) |
1x RAID or HBA (12 drives) |
Factory installed:
|
Rear drive bays | ||
2x 2.5-in. SAS/SATA hot-swap (rear) |
1x M1215 |
Factory installed:
|
4x 2.5-in. SAS/SATA hot-swap (rear) |
2x M1215 |
Factory installed:
|
2x 3.5-in. SAS/SATA hot-swap (rear) (Cascaded) |
1x RAID or HBA (12+2 drives)*** |
Factory installed:
|
2x 3.5-in. SAS/SATA hot-swap (rear) (Independent RAID) |
1x M1215 |
Factory installed:
|
* RAID or HBA indicates that any combination of the M1215, M5210, and N2215 storage controllers is supported up to a maximum quantity listed; the numbers in brackets (x+y+z) specify the quantity of drives connected to each of the controllers.
# Each PCIe SSD Extender Adapter (PN 00ML997) provides connectivity for up to two PCIe SSDs, and each adapter occupies a PCIe slot. For factory configured models, two or four PCIe SSD Extender Adapters (FC AS95) must be included in the configuration. For field upgrades, the PCIe SSD Upgrade Kit (PN 00FK677) includes two PCIe SSD Extenders.
** Requires the selection of 8x or 16x 2.5-in. hot-swap drive bays (with 16x 2.5-in. drive bays, the internal optical drive cannot be used).
## Requires the selection of 8x 2.5-in. hot-swap drive bays.
*** Two drives in the 2x 3.5-inch Rear HDD Kit are connected to the SAS expander on the 12-drive backplane, that is, to the same storage controller as 12 drives on the front.
Configuration notes:
- 24x 2.5-inch front drives are supported on storage dense models only (models without the Standard [feature code ATE5] or Advanced [feature code ATE6] OP Panel).
- 2x 2.5-inch rear drives (1x Rear 2x 2.5" HDD Kit) are supported on 2.5-inch and 3.5-inch drive bay models.
- The Rear 2.5" HDD Kit is installed in place of the PCIe Riser Card 1, and PCIe slots 1, 2 and 3 are not present. The kit includes special riser that provides PCIe 3.0 x8 slot for the M1215 RAID controller that is dedicated to 2x 2.5-inch rear drives.
-
4x 2.5-inch rear drives (2x Rear 2x 2.5" HDD Kits) are supported on 2.5-inch hot-swap drive bay models only.
- The first Rear 2.5" HDD Kit is installed in place of the PCIe Riser Card 1, and PCIe slots 1, 2 and 3 are not present.
- The second Rear 2.5" HDD Kit is installed in place of the PCIe Riser Card 2, and PCIe slots 6, 7 and 8 are not present.
- Each kit includes special riser that provides PCIe 3.0 x8 slot for the M1215 RAID controller that is dedicated to 2x 2.5-inch rear drives.
-
2x 3.5-inch rear drives are supported on 3.5-inch hot-swap drive bay models only.
- With 8x 3.5-inch HS drive bay models, the 2x 3.5-inch Rear HDD Kit is connected to a dedicated M1215 controller (Independent RAID).
- With 12x 3.5-inch HS drive bay models, the 2x 3.5-inch Rear HDD Kit can be connected to a dedicated M1215 controller (Independent RAID) or SAS expander on the 12-drive backplane (Cascaded).
- The Rear 3.5" HDD Kit is installed in place of PCIe Riser Card 2; PCIe slots 6, 7, and 8 are not present.
- For 8x 3.5-inch and 12x 3.5-inch drive bay models, either 1x Rear 2x 3.5" HDD Kit (Independent RAID) or 1x Rear 2x 2.5" HDD Kit (Independent RAID) can be used in the configuration, but not both.
- For 12x 3.5-inch drive bay models, either 1x Rear 2x 3.5" HDD Kit (Independent RAID) or 1x Rear 2x 3.5" HDD Kit (Cascaded) can be used in the configuration, but not both. If the Cascaded Kit is used, 1x Rear 2x 2.5" HDD Kit (Independent RAID) also can be used in the configuration.
-
NVMe PCIe SSDs are supported on 8x or 16x 2.5-inch SAS/SATA hot-swap drive bay models only.
- With one processor, up to one NVMe PCIe SDD Upgrade Kit is supported, and it requires one of the Riser 1 card options with PCIe x8 slots:
- For the Riser 1 options with 3x PCIe x8 slots (part numbers 00KA519 or 00KA498), the PCIe SSD extenders are supported in PCIe slots 1 and 2.
- For the Riser 1 options with 1x PCIe x8 slot (part number 00KA489), the PCIe SSD extenders are supported in PCIe slots 3 and 4.
- With two processors, up to two NVMe PCIe SDD Upgrade Kits are supported, and they require a combination of the Riser 1 and Riser 2 card options with PCIe x8 slots:
- For the Riser 1 and Riser 2 options with 3x PCIe x8 slots (part numbers 00KA519 [Riser 1] or 00KA498 [Riser 1 or Riser 2]), the PCIe SSD extenders are supported in PCIe slots 1 and 2 (Riser 1), and 6 and 7 (Riser 2).
- For the Riser 1 and Riser 2 options with 1x PCIe x8 slot (part number 00KA489), the PCIe SSD extenders are supported in PCIe slots 3, 4, 5, and 8.
- For 16x 2.5-inch SAS/SATA hot-swap drive bay configurations, the internal optical drive is not supported in the configurations with NVMe PCIe SSDs.
- If only one NVMe PCIe SSD Upgrade Kit is used in the configurations with two processors, up to one 2.5-inch Rear HDD Kit is supported. In other configurations with the NVMe PCIe SSD Upgrade Kits, the 2.5-inch Rear HDD Kit cannot be used.
- With one processor, up to one NVMe PCIe SDD Upgrade Kit is supported, and it requires one of the Riser 1 card options with PCIe x8 slots:
Controllers for internal storage
The following table lists the storage controllers and options used for internal storage of the System x3650 M5.
Note: SAS RAID controllers and HBAs are supported in low profile PCIe x8 slots on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
Description | Part number | Feature code | Maximum supported | I/O slots supported |
---|---|---|---|---|
12 Gb SAS/SATA controllers | ||||
ServeRAID M5210 SAS/SATA Controller | 46C9110 | A3YZ | 3 | 9, 4, 1, 6 |
ServeRAID M1215 SAS/SATA Controller | 46C9114 | A45W | 3 | 9, 4, 1, 6, 3, 8 |
N2215 SAS/SATA HBA | 47C8675 | A3YY | 3 | 9, 4, 1, 6, 2, 7, 5 |
Hardware upgrades for the M5210 (one per controller) | ||||
ServeRAID M5200 Series 1GB Cache/RAID 5 Upgrade | 47C8656 | A3Z0 | 3 | - |
ServeRAID M5200 Series 1GB Flash/RAID 5 Upgrade | 47C8660 | A3Z1 | 3 | - |
ServeRAID M5200 Series 2GB Flash/RAID 5 Upgrade | 47C8664 | A3Z2 | 3 | - |
ServeRAID M5200 Series 4GB Flash/RAID 5 Upgrade | 47C8668 | A3Z3 | 3 | - |
Features on Demand upgrades for the M5210 (system-wide)* | ||||
ServeRAID M5200 Series Zero Cache/RAID 5 Upgrade (FOD) | 47C8708 | A3Z6 | 1 | - |
ServeRAID M5200 Series RAID 6 Upgrade (FOD) | 47C8706 | A3Z5 | 1** | - |
ServeRAID M5200 Series Performance Accelerator (FOD) | 47C8710 | A3Z7 | 1** | - |
ServeRAID M5200 Series SSD Caching Enabler (FOD) | 47C8712 | A3Z8 | 1** | - |
Features on Demand upgrades for the M1215 (system-wide)* | ||||
ServeRAID M1200 Zero Cache/RAID 5 Upgrade (FOD) | 00AE930 | A5H5 | 1 | - |
PCIe extenders (for NVMe PCIe SSDs) | ||||
System x NVMe PCIe SSD Extender Adapter | 00ML997 | AS95 | 4 | 1, 2, 3, 4, 5, 6, 7, 8 |
* One FoD upgrade enables the feature on all ServeRAID adapters of the same family (M5200 or M1200) installed in the server.
** Requires cache memory upgrade (47C8656, 47C8660, 47C8664, or 47C8668).
The following table summarizes features of supported storage controllers.
Feature | M1215 | M5210 | N2215 |
Part number | 46C9114 | 46C9110 | 47C8675 |
Form factor | PCIe low profile | PCIe low profile | PCIe low profile |
Controller chip | LSI SAS3008 | LSI SAS3108 | LSI SAS3008 |
Host interface | PCIe 3.0 x8 | PCIe 3.0 x8 | PCIe 3.0 x8 |
Port interface | 12 Gbps SAS | 12 Gbps SAS | 12 Gbps SAS |
Number of ports | 8 | 8 | 8 |
Port connectors | 2x Mini-SAS HD x4 (SFF-8643) |
2x Mini-SAS HD x4 (SFF-8643) |
2x Mini-SAS HD x4 (SFF-8643) |
Drive interface | SAS, SATA | SAS, SATA | SAS, SATA |
Drive type | HDD, SSD, SED | HDD, SSD, SED | HDD, SSD |
Drive form factor | SFF, LFF | SFF, LFF | SFF, LFF |
Hot-swap drives | Yes | Yes | Yes |
Max devices | 32 (RAID); 64 (JBOD) | 240 | 1024 |
RAID levels | 0/1/10; Optional 5/50 (00AE930) |
0/1/10; Optional 5/50 (RAID 5 FoD, 47C8708, or cache upgrades); Optional 6/60 (47C8706) |
None |
JBOD mode | Yes | Yes (without cache) | Yes |
Cache | None |
1 GB no backup (47C8656)
1 GB flash backup (47C8660)
2 GB flash backup (47C8664)
4 GB flash backup (47C8668)
|
None |
SED support (SafeStore) | Yes (with RAID 5 FoD upgrade) |
Yes (with RAID 5 FoD upgrade or any cache upgrade) |
No |
Performance Accelerator (FastPath) | No | Optional (47C8710) | No |
SSD Caching (CacheCade Pro 2.0) | No | Optional (47C8712) | No |
For more information, see the list of Product Guides in the RAID adapters category:
https://lenovopress.com/servers/options/raid
The following table lists supported combinations of the storage controllers and drive types for the System x3650 M5 drive bay configurations.
Drive bay configuration | Storage Controller | Drive type | ||||||
---|---|---|---|---|---|---|---|---|
SAS HDD | NL SAS HDD | NL SATA HDD | SAS SED | SAS SSD | SATA SSD | PCIe SSD | ||
Front drive bays | ||||||||
8/16/24x 2.5-inch SAS/SATA hot-swap (front) |
M1215 | Yes | Yes | Yes | Yes* | Yes | Yes | No |
M5210 | Yes | Yes | Yes | Yes** | Yes | Yes | No | |
N2215 | Yes | Yes | Yes | No | Yes | Yes | No | |
8/12x 3.5-inch SAS/SATA hot-swap (front) |
M1215 | Yes | Yes | Yes | No | No | Yes | No |
M5210 | Yes | Yes | Yes | No | No | Yes | No | |
N2215 | Yes | Yes | Yes | No | No | Yes | No | |
4/8x 2.5-inch NVMe PCIe hot-swap (front) |
PCIe SSD Extender |
No | No | No | No | No | No | Yes |
Rear drive bays | ||||||||
2/4x 2.5-inch SAS/SATA hot-swap (rear; independent RAID) |
M1215 | Yes | Yes | Yes | Yes* | Yes | Yes | No |
2x 3.5-inch SAS/SATA hot-swap (rear; cascaded RAID)# |
M1215 | Yes | Yes | Yes | No | No | Yes | No |
M5210 | Yes | Yes | Yes | No | No | Yes | No | |
N2215 | Yes | Yes | Yes | No | No | Yes | No | |
2x 3.5-inch SAS/SATA hot-swap (rear; independent RAID) |
M1215 | Yes | Yes | Yes | No | No | Yes | No |
# 3.5" rear drives support cascaded connections only to the SAS expander on the 12-drive backplane (12x 3.5" drive bay models).
* SEDs are supported with the RAID 5 FoD upgrade (00AE930).
** SEDs are supported with the RAID 5 FoD upgrade (47C8708) or any cache upgrade (47C8656, 47C8660, 47C8664, 47C8668).
Drives for internal storage
The following tables list drive options for the System x3650 M5.
Description | Part number | Feature code | Maximum supported |
2.5-inch hot-swap HDDs - 12 Gbps SAS | |||
300GB 10K 12Gbps SAS 2.5" G3HS HDD | 00WG685 | AT89 | 28 |
300GB 15K 12Gbps SAS 2.5" G3HS HDD | 00WG660 | AT84 | 28 |
600GB 10K 12Gbps SAS 2.5" G3HS HDD | 00WG690 | AT8A | 28 |
600GB 15K 12Gbps SAS 2.5" G3HS HDD | 00WG665 | AT85 | 28 |
900GB 10K 12Gbps SAS 2.5" G3HS HDD | 00WG695 | AT8B | 28 |
900GB 15K 12Gbps SAS 2.5" G3HS 512e HDD | 01GV035 | AVKU | 28* |
1.2TB 10K 12Gbps SAS 2.5" G3HS HDD | 00WG700 | AT8C | 28 |
1.8TB 10K 12Gbps SAS 2.5" G3HS 512e HDD | 00NA271 | ASBM | 28 |
2.4TB 10K 12Gbps SAS 2.5" G3HS 512e HDD | 01GV070 | B0YT | 28* |
2.5-inch hot-swap HDDs - 12 Gbps NL SAS | |||
1TB 7.2K 12Gbps NL SAS 2.5'' G3HS HDD | 00NA491 | AT7Z | 28 |
2TB 7.2K 12Gbps NL SAS 2.5'' G3HS HDD | 00NA496 | AT80 | 28 |
2.5-inch hot-swap HDDs - 6 Gbps NL SATA | |||
500GB 7.2K 6Gbps NL SATA 2.5" G3HS HDD | 00AJ136 | A4TW | 28 |
1TB 7.2K 6Gbps NL SATA 2.5" G3HS HDD | 00AJ141 | A4TX | 28 |
2TB 7.2K 6Gbps NL SATA 2.5'' G3HS 512e HDD | 00NA526 | AT81 | 28 |
2.5-inch hot-swap SEDs - 12 Gbps SAS | |||
300GB 10K 12Gbps SAS 2.5" G3HS SED | 00WG705 | AT8D | 28 |
600GB 10K 12Gbps SAS 2.5" G3HS SED | 00WG710 | AT8E | 28 |
900GB 10K 12Gbps SAS 2.5" G3HS SED | 00WG715 | AT8F | 28 |
1.2TB 10K 12Gbps SAS 2.5" G3HS SED | 00WG720 | AT8G | 28 |
2.5-inch hot-swap SEDs - 12 Gbps NL SAS | |||
2TB 7.2K 12Gbps NL SAS 2.5'' G3HS 512e FIPS 140-2 SED | 01GR670 | AUCF | 28* |
2.5-inch hot-swap SSDs - Enterprise Performance 12 Gbps SAS (SS300) | |||
400GB Enterprise Performance 12G SAS G3HS 2.5" SSD | 01GV711 | AVL0 | 28* |
800GB Enterprise Performance 12G SAS G3HS 2.5" SSD | 01GV716 | AVL1 | 28* |
1.6TB Enterprise Performance 12G SAS G3HS 2.5" SSD | 01GV721 | AVL2 | 28* |
2.5-inch hot-swap SSDs - Enterprise 12 Gbps SAS | |||
200GB 12G SAS 2.5" MLC G3HS Enterprise SSD | 00FN379 | AS7C | 28 |
400GB 12G SAS 2.5" MLC G3HS Enterprise SSD | 00FN389 | AS7E | 28 |
800GB 12G SAS 2.5" MLC G3HS Enterprise SSD | 00FN399 | AS7G | 28 |
1.6TB 12G SAS 2.5" MLC G3HS Enterprise SSD | 00FN409 | AS7J | 28 |
2.5-inch hot-swap SSDs - Enterprise Mainstream 12 Gbps SAS | |||
400GB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD | 00YC460 | AT9M | 28 |
800GB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD | 00YC465 | AT9N | 28 |
1.6TB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD | 00YC470 | AT9P | 28 |
2.5-inch hot-swap SSDs - PM1635a Enterprise Mainstream 12 Gbps SAS | |||
PM1635a 400GB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD | 01GV761 | AWEY | 28* |
PM1635a 800GB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD | 01GV766 | AWEZ | 28* |
PM1635a 1.6TB Enterprise Mainstream 12Gb SAS G3HS 2.5" SSD | 01GV771 | AWF0 | 28* |
2.5-inch hot-swap SSDs - Enterprise 6 Gbps SAS | |||
200GB SAS 2.5" MLC G3HS Enterprise SSD | 00AJ207 | A4UA | 28 |
2.5-inch hot-swap SSDs - Enterprise Capacity 12 Gbps SAS | |||
PM1633a 3.84TB Enterprise Capacity 12Gb SAS G3HS 2.5" SSD | 01GR786 | AVKV | 28* |
PM1633a 7.68TB Enterprise Capacity 12Gb SAS G3HS 2.5" SSD | 01GR771 | AUEJ | 28* |
2.5-inch hot-swap SSDs - Enterprise Capacity 6 Gbps SAS | |||
3.84TB 6Gb SAS Enterprise Capacity G3HS MLC SSD | 00NA671 | ASW6 | 28 |
2.5-inch hot-swap SSDs - Enterprise Performance 6 Gbps SATA | |||
Intel S3710 800GB Enterprise Performance SATA G3HS 2.5" SSD | 00YC330 | AT9E | 28 |
2.5-inch hot-swap SSDs - Enterprise Performance PCIe 3.0 x4** | |||
Intel P3700 400GB NVMe 2.5" G3HS Enterprise Performance PCIe SSD | 00YA818 | AT7V | 8 |
Intel P3700 800GB NVMe 2.5" G3HS Enterprise Performance PCIe SSD | 00YA821 | AT7W | 8 |
Intel P3700 1.6TB NVMe 2.5" G3HS Enterprise Performance PCIe SSD | 00YA824 | AT7X | 8 |
Intel P3700 2.0TB NVMe 2.5" G3HS Enterprise Performance PCIe SSD | 00YA827 | AT7Y | 8 |
2.5-inch hot-swap SSDs - 5100 Enterprise Mainstream 6 Gbps SATA | |||
5100 240GB Enterprise Mainstream SATA G3HS 2.5" SSD | 01GV843 | AXFV | 28* |
5100 480GB Enterprise Mainstream SATA G3HS 2.5" SSD | 01GV848 | AXFW | 28* |
5100 960GB Enterprise Mainstream SATA G3HS 2.5" SSD | 01GV853 | AXFX | 28* |
5100 1.92TB Enterprise Mainstream SATA G3HS 2.5" SSD | 01GV858 | AXFY | 28* |
5100 3.84TB Enterprise Mainstream SATA G3HS 2.5" SSD | 01GV863 | AXFZ | 28* |
2.5-inch hot-swap SSDs - S3610 Enterprise Mainstream 6 Gbps SATA | |||
Intel S3610 480GB Enterprise Mainstream SATA G3HS 2.5" SSD | 00YK212 | AU3C | 28 |
Intel S3610 800GB Enterprise Mainstream SATA G3HS 2.5" SSD | 00YK217 | AU3D | 28 |
Intel S3610 1.2TB Enterprise Mainstream SATA G3HS 2.5" SSD | 00YK222 | AU3E | 28 |
Intel S3610 1.6TB Enterprise Mainstream SATA G3HS 2.5" SSD | 00YK227 | AU3F | 28 |
2.5-inch hot-swap SSDs - S4600 Enterprise Mainstream 6 Gbps SATA | |||
Intel S4600 240GB Enterprise Mainstream SATA G3HS 2.5" SSD | 4XB7A08499 | B10A | 28* |
Intel S4600 480GB Enterprise Mainstream SATA G3HS 2.5" SSD | 7SD7A05713 | B10B | 28* |
Intel S4600 960GB Enterprise Mainstream SATA G3HS 2.5" SSD | 7SD7A05712 | B10C | 28* |
Intel S4600 1.92TB Enterprise Mainstream SATA G3HS 2.5" SSD | 7SD7A05711 | B10D | 28* |
2.5-inch hot-swap SSDs - Enterprise Mainstream PCIe 3.0 x4** | |||
960GB NVMe 2.5" Enterprise Mainstream PCIe SSD | 00YK284 | AVP1 | 8* |
1.92TB NVMe 2.5" Enterprise Mainstream PCIe SSD | 00YK285 | AVP2 | 8* |
2.5-inch hot-swap SSDs - PM963 Enterprise Mainstream PCIe 3.0 x4** | |||
PM963 1.92TB NVMe 2.5" Enterprise Value PCIe SSD | 01GR660 | AVPN | 8* |
PM963 3.84TB NVMe 2.5" Enterprise Value PCIe SSD | 01GT715 | AVPP | 8* |
2.5-inch hot-swap SSDs - M500DC Enterprise Mainstream 6 Gbps SATA | |||
M500DC 480GB Enterprise Mainstream Plus SATA G3HS 2.5" SSD | 00YC529 | ATDW | 28 |
2.5-inch hot-swap SSDs - 5100 Enterprise Entry 6 Gbps SATA | |||
5100 480GB Enterprise Entry SATA G3HS 2.5" SSD | 01KR496 | AXGL | 28* |
5100 960GB Enterprise Entry SATA G3HS 2.5" SSD | 01KR501 | AXGM | 28* |
5100 1.92TB Enterprise Entry SATA G3HS 2.5" SSD | 01KR506 | AXGN | 28* |
5100 3.84TB Enterprise Entry SATA G3HS 2.5" SSD | 01KR511 | AXGP | 28* |
2.5-inch hot-swap SSDs - Enterprise Entry 6 Gbps SATA | |||
1.92TB Enterprise Entry SATA G3HS 2.5" SSD | 01GR711 | AUE7 | 28 |
2.5-inch hot-swap SSDs - S3520 Enterprise Entry 6 Gbps SATA | |||
Intel S3520 240GB Enterprise Entry SATA G3HS 2.5" SSD | 01GR726 | AUEM | 28 |
Intel S3520 480GB Enterprise Entry SATA G3HS 2.5" SSD | 01GR731 | AUEP | 28 |
Intel S3520 800GB Enterprise Entry SATA G3HS 2.5" SSD | 01KR466 | AXGB | 28 |
Intel S3520 960GB Enterprise Entry SATA G3HS 2.5" SSD | 01GR736 | AUER | 28 |
Intel S3520 1.2TB Enterprise Entry SATA G3HS 2.5" SSD | 01GR802 | AXGD | 28 |
Intel S3520 1.6TB Enterprise Entry SATA G3HS 2.5" SSD | 01GR817 | AXGF | 28 |
2.5-inch hot-swap SSDs - S4500 Enterprise Entry 6 Gbps SATA | |||
Intel S4500 240GB Enterprise Entry SATA G3HS 2.5" SSD | 7SD7A05732 | B0Z8 | 28* |
Intel S4500 480GB Enterprise Entry SATA G3HS 2.5" SSD | 7SD7A05731 | B0Z9 | 28* |
Intel S4500 960GB Enterprise Entry SATA G3HS 2.5" SSD | 7SD7A05730 | B0ZA | 28* |
Intel S4500 1.92TB Enterprise Entry SATA G3HS 2.5" SSD | 4XB7A08493 | B0ZB | 28* |
Intel S4500 3.84TB Enterprise Entry SATA G3HS 2.5" SSD | 4XB7A08494 | B0ZC | 28* |
2.5-inch hot-swap SSDs - PM863a Enterprise Entry 6 Gbps SATA | |||
PM863a 240GB Enterprise Entry SATA G3HS 2.5" SSD | 01GR836 | AVHP | 28 |
PM863a 480GB Enterprise Entry SATA G3HS 2.5" SSD | 01GR841 | AVHQ | 28 |
PM863a 960GB Enterprise Entry SATA G3HS 2.5" SSD | 01GR846 | AVHR | 28 |
2.5-inch hot-swap SSDs - Enterprise Value 6 Gbps SATA | |||
120GB SATA 2.5" MLC G3HS Enterprise Value SSD | 00AJ395 | A577 | 28 |
240GB SATA 2.5" MLC G3HS Enterprise Value SSD | 00AJ400 | A578 | 28 |
480GB SATA 2.5" MLC G3HS Enterprise Value SSD | 00AJ405 | A579 | 28 |
800GB SATA 2.5" MLC G3HS Enterprise Value SSD | 00AJ410 | A57A | 28 |
2.5-inch hot-swap SSDs - Enterprise Value PCIe 3.0 x4** | |||
Intel P3600 400GB NVMe 2.5" G3HS Enterprise Value PCIe SSD | 90Y3227 | A5RW | 8 |
Intel P3600 800GB NVMe 2.5" G3HS Enterprise Value PCIe SSD | 90Y3230 | A5RX | 8 |
Intel P3600 1.6TB NVMe 2.5" G3HS Enterprise Value PCIe SSD | 90Y3233 | A5RY | 8 |
Intel P3600 2.0TB NVMe 2.5" G3HS Enterprise Value PCIe SSD | 90Y3236 | A5RZ | 8 |
2.5-inch hot-swap SED SSDs - Enterprise Performance 12 Gbps SAS (SS300) | |||
400GB Enterprise Performance 12Gbps SAS G3HS 2.5" SSD FIPS | 7SD7A05748 | AXG5 | 28* |
800GB Enterprise Performance 12Gbps SAS G3HS 2.5" SSD FIPS | 7SD7A05747 | AXG6 | 28* |
1.6TB Enterprise Performance 12Gbps SAS G3HS 2.5" SSD FIPS | 7SD7A05746 | AXG7 | 28* |
2.5-inch hot-swap SED SSDs - Enterprise 12 Gbps SAS | |||
HGST SSC+ 400GB 12Gb SAS FIPS SED 2.5" Enterprise G3HS SSD | 01GR600 | AUCC | 28* |
HGST SSC+ 800GB 12Gb SAS FIPS SED 2.5" Enterprise G3HS SSD | 01GR605 | AUCD | 28* |
HGST SSC+ 1.6TB 12Gb SAS FIPS SED 2.5" Enterprise G3HS SSD | 01GR610 | AUCE | 28* |
* Not supported with the Intel Xeon processor E5-2600 v3 product family.
** NVMe PCIe SSDs support informed hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.
Description | Part number | Feature code | Maximum supported |
3.5-inch hot-swap HDDs - 12 Gbps SAS | |||
300GB 15K 12Gbps SAS 3.5" G2HS HDD (2.5" SSD with 3.5" tray) | 00WG675 | AT87 | 14 |
600GB 15K 12Gbps SAS 3.5" G2HS HDD (2.5" SSD with 3.5" tray) | 00WG680 | AT88 | 14 |
900GB 15K 12Gbps SAS 3.5" G2HS 512e HDD (2.5" SSD with 3.5" tray) | 01GV040 | AVL9 | 14* |
3.5-inch hot-swap HDDs - 12 Gbps NL SAS | |||
1TB 7.2K 12Gbps NL SAS 3.5" G2HS HDD | 00YL702 | ATYM | 14 |
2TB 7.2K 12Gbps NL SAS 3.5" G2HS HDD | 00YK000 | ATYL | 14 |
2TB 7.2K 12Gbps NL SAS 3.5" G2HS 512e HDD | 00FN188 | A5VP | 14 |
4TB 7.2K 12Gbps NL SAS 3.5" G2HS HDD | 00YK005 | ATYN | 14 |
6TB 7.2K 12Gbps NL SAS 3.5" G2HS 512e HDD | 00FN228 | A5VR | 14 |
8TB 7.2K 12Gbps NL SAS 3.5" G2HS 512e HDD | 00WH121 | ATRS | 14 |
10TB 7.2K 12Gbps NL SAS 3.5" G2HS 512e HDD | 00YK336 | AU7R | 14 |
3.5-inch hot-swap HDDs - 6 Gbps NL SAS | |||
2TB 7.2K 6Gbps NL SAS 3.5" G2HS HDD | 90Y8572 | A2U0 | 14 |
3.5-inch hot-swap HDDs - 6 Gbps NL SATA | |||
500GB 7.2K 6Gbps NL SATA 3.5" G2HS HDD | 81Y9786 | A22Y | 14 |
1TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD | 81Y9790 | A22P | 14 |
2TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD | 81Y9794 | A22T | 14 |
4TB 7.2K 6Gbps NL SATA 3.5" G2HS HDD | 49Y6002 | A3W9 | 14 |
4TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD | 00FN143 | A5VH | 14 |
6TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD | 00FN173 | A5VM | 14 |
8TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD | 00WH126 | ATRT | 14 |
10TB 7.2K 6Gbps NL SATA 3.5" G2HS 512e HDD | 00YK341 | AU7S | 14 |
3.5-inch hot-swap SEDs - 12 Gbps NL SAS | |||
2TB 7.2K 12Gbps NL SAS 3.5'' G2HS 512e FIPS 140-2 SED | 01GR676 | AUCM | 14* |
4TB 7.2K 12Gbps NL SAS 3.5'' G2HS FIPS 140-2 SED | 01GR682 | AUCN | 14* |
6TB 7.2K 12Gbps NL SAS 3.5'' G2HS 512e FIPS 140-2 SED | 01GR688 | AUCP | 14* |
8TB 7.2K 12Gbps NL SAS 3.5'' G2HS 512e FIPS 140-2 SED | 01GR694 | AUCQ | 14* |
3.5-inch hot-swap SSDs - Enterprise Performance 12 Gbps SAS (SS300) | |||
400GB Enterprise Performance 12G SAS HS 3.5" SSD | 01GV726 | AVL3 | 14* |
800GB Enterprise Performance 12G SAS HS 3.5" SSD | 01GV731 | AVL4 | 14* |
1.6TB Enterprise Performance 12G SAS HS 3.5" SSD | 01GV736 | AVL5 | 14* |
3.5-inch hot-swap SSDs - Enterprise 12 Gbps SAS | |||
1.6TB 12Gb SAS 3.5" MLC HS Enterprise SSD | 01GR881 | AUBU | 14 |
3.5-inch hot-swap SSDs - Enterprise Capacity 12 Gbps SAS | |||
PM1633a 3.84TB Enterprise Capacity 12Gb SAS HS 3.5" SSD | 01GR791 | AVKW | 14* |
3.5-inch hot-swap SSDs - Enterprise Capacity 6 Gbps SAS | |||
3.84TB 6Gb SAS 3.5" Enterprise Capacity HS MLC SSD | 01GR871 | AUBS | 14 |
3.5-inch hot-swap SSDs - Enterprise Performance 6 Gbps SATA | |||
Intel S3710 800GB Enterprise Performance SATA HS 3.5" SSD | 00YC345 | AT9H | 14 |
3.5-inch hot-swap SSDs - 5100 Enterprise Mainstream 6 Gbps SATA | |||
5100 240GB Enterprise Mainstream SATA HS 3.5" SSD | 01GV868 | AXG0 | 14* |
5100 480GB Enterprise Mainstream SATA HS 3.5" SSD | 01GV873 | AXG1 | 14* |
5100 960GB Enterprise Mainstream SATA HS 3.5" SSD | 01GV878 | AXG2 | 14* |
5100 1.92TB Enterprise Mainstream SATA HS 3.5" SSD | 01GV883 | AXG3 | 14* |
5100 3.84TB Enterprise Mainstream SATA HS 3.5" SSD | 01GV090 | AXG4 | 14* |
3.5-inch hot-swap SSDs - S3610 Enterprise Mainstream 6 Gbps SATA | |||
Intel S3610 480GB Enterprise Mainstream SATA HS 3.5" SSD | 00YK237 | AU3H | 14 |
Intel S3610 800GB Enterprise Mainstream SATA HS 3.5" SSD | 00YK242 | AU3J | 14 |
Intel S3610 1.2TB Enterprise Mainstream SATA HS 3.5" SSD | 00YK247 | AU3K | 14 |
Intel S3610 1.6TB Enterprise Mainstream SATA HS 3.5" SSD | 00YK252 | AU3L | 14 |
3.5-inch hot-swap SSDs (2.5" SSD in 3.5" drive tray) - S4600 Enterprise Mainstream 6 Gbps SATA | |||
Intel S4600 240GB Enterprise Mainstream SATA HS 3.5" SSD | 4XB7A08500 | B10E | 14* |
Intel S4600 480GB Enterprise Mainstream SATA HS 3.5" SSD | 7SD7A05710 | B10F | 14* |
Intel S4600 960GB Enterprise Mainstream SATA HS 3.5" SSD | 7SD7A05709 | B10G | 14* |
Intel S4600 1.92TB Enterprise Mainstream SATA HS 3.5" SSD | 7SD7A05708 | B10H | 14* |
3.5-inch hot-swap SSDs - 5100 Enterprise Entry 6 Gbps SATA | |||
5100 480GB Enterprise Entry SATA HS 3.5" SSD | 01KR516 | AXGQ | 14* |
5100 960GB Enterprise Entry SATA HS 3.5" SSD | 01KR521 | AXGR | 14* |
5100 1.92TB Enterprise Entry SATA HS 3.5" SSD | 01KR526 | AXGS | 14* |
5100 3.84TB Enterprise Entry SATA HS 3.5" SSD | 01KR531 | AXGT | 14* |
3.5-inch hot-swap SSDs - PM863a Enterprise Entry 6 Gbps SATA | |||
PM863a 240GB Enterprise Entry SATA HS 3.5" SSD | 01GR899 | AVHS | 14 |
PM863a 480GB Enterprise Entry SATA HS 3.5" SSD | 01GR851 | AVHT | 14 |
PM863a 960GB Enterprise Entry SATA HS 3.5" SSD | 01GR856 | AVHU | 14 |
3.5-inch hot-swap SSDs - S3520 Enterprise Entry 6 Gbps SATA | |||
Intel S3520 240GB Enterprise Entry SATA HS 3.5" SSD | 01GR741 | AUF0 | 14 |
Intel S3520 480GB Enterprise Entry SATA HS 3.5" SSD | 01GR746 | AUF1 | 14 |
Intel S3520 800GB Enterprise Entry SATA HS 3.5" SSD | 01KR471 | AXGC | 14 |
Intel S3520 960GB Enterprise Entry SATA HS 3.5" SSD | 01GR751 | AUF2 | 14 |
Intel S3520 1.2TB Enterprise Entry SATA HS 3.5" SSD | 01GR807 | AXGE | 14 |
Intel S3520 1.6TB Enterprise Entry SATA HS 3.5" SSD | 01GR822 | AXGG | 14 |
3.5-inch hot-swap SSDs (2.5" SSD in 3.5" drive tray) - S4500 Enterprise Entry 6 Gbps SATA | |||
Intel S4500 240GB Enterprise Entry SATA HS 3.5" SSD | 7SD7A05729 | B0ZD | 14* |
Intel S4500 480GB Enterprise Entry SATA HS 3.5" SSD | 7SD7A05728 | B0ZE | 14* |
Intel S4500 960GB Enterprise Entry SATA HS 3.5" SSD | 7SD7A05727 | B0ZF | 14* |
Intel S4500 1.92TB Enterprise Entry SATA HS 3.5" SSD | 4XB7A08495 | B0ZG | 14* |
Intel S4500 3.84TB Enterprise Entry SATA HS 3.5" SSD | 4XB7A08496 | B0ZH | 14* |
3.5-inch hot-swap SSDs - Enterprise Entry 6 Gbps SATA | |||
1.92TB Enterprise Entry SATA HS 3.5" SSD | 01GR721 | AUE9 | 14 |
3.5-inch hot-swap SSDs - Enterprise Value 6 Gbps SATA | |||
120GB SATA 3.5" MLC HS Enterprise Value SSD | 00AJ435 | A57F | 14 |
480GB SATA 3.5" MLC HS Enterprise Value SSD | 00AJ445 | A57H | 14 |
3.5-inch hot-swap SED SSDs - Enterprise Performance 12 Gbps SAS (SS300) | |||
400GB Enterprise Performance 12Gb SAS HS 3.5" SSD FIPS | 7SD7A05745 | AXG8 | 14* |
800GB Enterprise Performance 12Gb SAS HS 3.5" SSD FIPS | 7SD7A05744 | AXG9 | 14* |
1.6TB Enterprise Performance 12Gb SAS HS 3.5" SSD FIPS | 7SD7A05743 | AXGA | 14* |
* Not supported with the Intel Xeon processor E5-2600 v3 product family.
Optical drives
The System x3650 M5 server supports the optical drive options listed in the following table. Storage dense models with 12x 3.5-inch or up to 24x 2.5-inch drive bays on the front do not support internal optical drive; a supported external optical drive can be used instead.
Description | Part number | Feature code | Maximum supported |
Optical drives | |||
Ultraslim 9.5mm SATA DVD-ROM | 00AM066 | A5KG | 1 |
Ultraslim 9.5mm SATA Multi Burner | 00AM067 | A5KH | 1 |
Optical drive cable (Required) | |||
System x3650 M5 ODD Cable Kit | 00AL956 | None* | 1 |
* The ODD Cable Kit part number (00AL956) includes two cables: ODD Cable for 3.5" Model (feature code A5GM) and ODD Cable for 2.5" Model (feature code A5V7).
Ultraslim 9.5mm SATA DVD-ROM (part number 00AM066) supports the following media and speeds for reading:
- CD-ROM/CD-DA (DAE) 24X
- CD-R/RW 24X
- DVD-ROM 8X
- DVD-R 8X
- DVD+R 8X
- DVD-R DL 6X
- DVD+R DL 8X
- DVD-RW 8X
- DVD+RW 8X
- DVD-RAM (4.7 GB) 5X
Ultraslim 9.5mm SATA Multi Burner (part number 00AM067) supports the same media and speeds for reading as DVD-ROM (part number 00AM066), and it supports the following media and speeds for writing:
- CD-R 24X
- CD-RW 4X, High Speed CD-RW 10X, Ultra Speed CD-RW 24X
- DVD-R 8X
- DVD+R 8X
- DVD-R DL 6X
- DVD+R DL 6X
- DVD-RW 6X
- DVD+RW 8X
- DVD-RAM 5X
I/O expansion
The System x3650 M5 server supports up to nine PCIe slots: one slot on the system planar that is dedicated for an internal storage controller, two regular PCIe slots on the system planar, and up to six PCIe slots with different riser cards installed into two riser sockets on the system planar (one riser socket supports installation of one riser card). The slot form factors are as follows:
- Slot 1: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, full-length (PCIe x16 slot is double-wide)
- Slot 2: PCIe 3.0 x8; full-height, full-length (not present if the slot 1 is PCIe x16)
- Slot 3: PCIe 3.0 x8 or ML2; full-height, half-length
- Slot 4: PCIe 3.0 x8; low profile (vertical slot on system planar)
- Slot 5: PCIe 3.0 x8; low profile (vertical slot on system planar)
- Slot 6: PCIe 3.0 x16 or PCIe 3.0 x8; full-height, full-length (PCIe x16 slot is double-wide)
- Slot 7: PCIe 3.0 x8; full-height, full-length (not present if the slot 6 is PCIe x16)
- Slot 8: PCIe 3.0 x8; full-height, half-length
- Slot 9: PCIe 3.0 x8 (dedicated for an internal RAID controller)
Notes:
- Slots 5, 6, 7, and 8 require the second processor to be installed.
- For customers who need three PCIe 3.0 x16 slots in the System x3650 M5 for their specific workloads, a special base model 8871-AC3 that can be configured with 3x PCIe 3.0 x16 slots (onboard slot 5 + slots 1 and 6 on the riser cards) is available via CTO (x-config only).
The locations of the PCIe slots are shown in the following figure.
Figure 14. Slot locations
Riser 1 supplies slots 1, 2, and 3, and Riser 2 supplies slots 6, 7, and 8. The slots that are available for use depend on the number of riser cards that are installed and whether the second processor is installed, as shown in the following table.
Notes:
- PCIe x8 riser card part numbers are 00KA519 (Riser Card 1) and 00KA498 (Riser Card 1 or 2).
- PCIe x16 riser card part numbers are 00KA504 (Riser Card 1) and 00KA489 (Riser Card 1 or 2).
Riser Card 1 | Riser Card 2 | Slots available for use |
One processor | ||
None | None | 4, 9 |
PCIe x8 | None | 1, 2, 3, 4, 9 |
PCIe x16 | None | 1, 3, 4, 9 |
Two processors | ||
None | None | 4, 5, 9 |
PCIe x8 | None | 1, 2, 3, 4, 5, 9 |
PCIe x8 | PCIe x8 | 1, 2, 3, 4, 5, 6, 7, 8, 9 |
PCIe x8 | PCIe x16 | 1, 2, 3, 4, 5, 6, 8, 9 |
PCIe x16 | None | 1, 3, 4, 5, 9 |
PCIe x16 | PCIe x8 | 1, 3, 4, 5, 6, 7, 8, 9 |
PCIe x16 | PCIe x16 | 1, 3, 4, 5, 6, 8, 9 |
Standard models do not include any riser cards. The following table lists available PCIe riser card options.
Description | Part number | Feature code | Maximum supported |
Riser 1 options (PCIe x8 riser supplies slots 1, 2 and 3; PCIe x16 riser supplies slots 1 and 3) | |||
System x3650 M5 PCIe Riser 1 (1 x16 FH/FL + 1 x8 ML2 Slots) | 00KA504 | A5FR | 1 |
System x3650 M5 PCIe Riser 1 (2 x8 FH/FL + 1 x8 ML2 Slots) | 00KA519 | A5FQ | 1 |
System x3650 M5 PCIe Riser (1 x16 FH/FL + 1 x8 FH/HL Slots) | 00KA489 | A5FN | 1 |
System x3650 M5 PCIe Riser (2 x8 FH/FL + 1 x8 FH/HL Slots) | 00KA498 | A5FP | 1 |
Riser 2 options (PCIe x8 riser supplies slots 6, 7 and 8; PCIe x16 riser supplies slots 6 and 8) | |||
System x3650 M5 PCIe Riser (1 x16 FH/FL + 1 x8 FH/HL Slots) | 00KA489 | A5R5 | 1 |
System x3650 M5 PCIe Riser (2 x8 FH/FL + 1 x8 FH/HL Slots) | 00KA498 | A5R6 | 1 |
Serial port bracket | |||
COM Port Bracket | 00KA161 | A5AN | 1 |
Riser option part numbers 00KA489 and 00KA498 can be installed in both riser slots 1 and 2; for CTO or special bid orders these option part numbers have different feature codes depending on the riser slot into which they are installed.
The COM Port Bracket, part number 00KA161, is used for mounting the external serial port on the rear of the System x3650 M5. This option includes the bracket and the cable. The COM Port option is mounted in place of the PCIe slot 5, and the PCIe slot 5 cannot be used.
Network adapters
The System x3650 M5 supports four integrated Gigabit Ethernet ports. Optionally, the server supports ML2 adapters that are installed in the custom ML2 slot provided by the PCIe ML2 riser cards (part numbers 00KA504 and 00KA519). This slot supports adapters with either two 10 Gb ports or four Gigabit Ethernet ports and supports direct connectivity to the IMM2.1 service processor for out-of-band systems management.
The integrated network interface controller (NIC) has the following features:
- A Broadcom BCM5719 chip
- Four Gigabit Ethernet ports
- NIC Teaming (load balancing and failover)
- Ethernet features:
- Compliant with 1 Gb Ethernet IEEE 802.3, 802.3u, and 802.3ab PHY specifications
- Integrated PHY for 10/100/1000 Mbps for multispeed, full, and half-duplex auto-negotiation
- Automatic MDI crossover
- IEEE 802.3x-compliant flow control support
- IEEE 1588 protocol and 802.1AS time synchronization implementation
- IEEE802.3az - Energy Efficient Ethernet (EEE)
- I/O Virtualization features:
- I/O Virtualization support for VMware NetQueue and Microsoft virtual machine queue (VMQ)
- Function Level Reset (FLR)
- IEEE 802.1q Virtual Local Area Network (VLAN) tagging support
- Stateless offload and performance features:
- TCP, IP, and User Datagram Protocol (UDP) checksum offload
- TCP segmentation offload (TCO)
- Large Send Offload (LSO)
- Receive Side Scaling (RSS) and Transmit Side Scaling (TSS)
- Message Signal Interrupt (MSI) and Message Signal Interrupt Extension (MSI-X) support
- Support for jumbo frames up to 9600 bytes
The following table lists additional supported Ethernet network adapters, transceivers, and cables.
Description | Part number | Feature code | Maximum supported# | I/O slots supported |
---|---|---|---|---|
100 Gb Ethernet / EDR InfiniBand - PCIe | ||||
Mellanox ConnectX-4 1x100GbE/EDR IB QSFP28 VPI Adpt. | 00KH924 | ASWQ | 1 / 2* | 1, 6† |
Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adpt. | 00MM960 | ATRP | 1 / 2* | 1, 6† |
Intel Omni-Path - PCIe | ||||
Intel OPA 100 Series Single-port PCIe 3.0 x8 HFA | 00WE023 | AU0A | 2 / 2* | 1, 2, 4, 5, 6, 7 |
Intel OPA 100 Series Single-port PCIe 3.0 x16 HFA | 00WE027 | AU0B | 1 / 2* | 1, 6† |
40 Gb Ethernet / FDR InfiniBand - ML2 | ||||
Mellanox ConnectX-3 Pro ML2 2x40GbE/FDR VPI Adapter | 00FP650 | A5RK | 1* | 3 |
40 Gb Ethernet - PCIe | ||||
Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter | 00MM950 | ATRN | 3 / 6* | 1, 2, 3, 4, 5, 6, 7, 8‡ |
40 Gb Ethernet / FDR InfiniBand - PCIe | ||||
Mellanox ConnectX-3 2x40GbE/FDR IB VPI QSFP+ Adapter | 00D9550 | A3PN | 3 / 6* | 1, 2, 3, 4, 5, 6, 7, 8‡ |
25 Gb Ethernet - ML2 | ||||
Mellanox ConnectX-4 Lx ML2 1x25GbE SFP28 Adapter | 00MN990 | ATZR | 1* | 3 |
25 Gb Ethernet - PCIe | ||||
Mellanox ConnectX-4 Lx 2x25GbE SFP28 Adapter | 01GR250 | AUAJ | 3 / 6* | 1, 2, 3, 4, 5, 6, 7, 8‡ |
10 Gb Ethernet - ML2 | ||||
Broadcom NetXtreme II ML2 Dual Port 10GbaseT | 00D2026 | A40S | 1 | 3 |
Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ | 00D2028 | A40T | 1* | 3 |
Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter | 00AG560 | AT7U | 1* | 3 |
Emulex VFA5 ML2 FCoE/iSCSI License (FoD) (Upgrade for 00AG560 - one per adapter) |
00D8544 | A4NZ | 1 | - |
Emulex VFA5.2 ML2 2x10GbE SFP+ Adapter & FCoE/iSCSI | 01CV770 | AU7Z | 1* | 3 |
Intel X540 ML2 Dual Port 10GbaseT Adapter | 00D1994 | A40P | 1 | 3 |
Intel X710-DA2 ML2 2x10GbE SFP+ Adapter | 00JY940 | ATRH | 1* | 3 |
10 Gb Ethernet - PCIe | ||||
Broadcom NetXtreme 2x10GbE BaseT Adapter | 44T1370 | A5GZ | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
Broadcom NetXtreme Dual Port 10GbE SFP+ Adapter | 94Y5180 | A4Z6 | 3 / 6* | 1, 2, 3, 4, 5, 6, 7, 8‡ |
Emulex VFA5 2x10 GbE SFP+ PCIe Adapter | 00JY820 | A5UT | 3 / 6* | 1, 2, 3, 4, 5, 6, 7, 8‡ |
Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter | 00AG570 | AT7S | 3 / 6* | 1, 2, 3, 4, 5, 6, 7, 8‡ |
Emulex VFA5 FCoE/iSCSI SW for PCIe Adapter (FoD) (Upgrade for 00JY820 and 00AG570 - one per adapter) |
00JY824 | A5UV | 3 / 6 | - |
Emulex VFA5 2x10 GbE SFP+ Adapter & FCoE/iSCSI SW | 00JY830 | A5UU | 3 / 6* | 1, 2, 3, 4, 5, 6, 7, 8‡ |
Emulex VFA5.2 2x10 GbE SFP+ Adapter & FCoE/iSCSI SW | 00AG580 | AT7T | 3 / 6* | 1, 2, 3, 4, 5, 6, 7, 8‡ |
Intel X520 Dual Port 10GbE SFP+ Adapter | 49Y7960 | A2EC | 4 / 8* | 1, 2, 3, 4, 5, 6, 7, 8 |
Intel X540-T2 Dual Port 10GBaseT Adapter | 49Y7970 | A2ED | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
Intel X550-T1 Single Port 10GBase-T Adapter | 00MM850 | ATRY | 4 / 8§ | 1, 2, 3, 4, 5, 6, 7, 8 |
Intel X550-T2 Dual Port 10GBase-T Adapter | 00MM860 | ATPX | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
Intel X710-DA2 2x10GbE SFP+ Adapter | 01DA900 | AU2Y | 3 / 6* | 1, 2, 3, 4, 5, 6, 7, 8‡ |
Mellanox ConnectX-3 10 GbE Adapter | 00D9690 | A3PM | 3 / 6* | 1, 2, 3, 4, 5, 6, 7, 8‡ |
1 Gb Ethernet - ML2 | ||||
Intel I350-T4 ML2 Quad Port GbE Adapter | 00D1998 | A40R | 1 | 3 |
1 Gb Ethernet - PCIe | ||||
Broadcom NetXtreme 2xGbE BaseT Adapter | 42C1780 | 2995 | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
Broadcom NetXtreme I Dual Port GbE Adapter | 90Y9370 | A2V4 | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
Broadcom NetXtreme I Quad Port GbE Adapter | 90Y9352 | A2V3 | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
Intel I350-F1 1xGbE Fiber Adapter | 00AG500 | A56K | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
Intel I350-T2 2xGbE BaseT Adapter | 00AG510 | A56L | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
Intel I350-T4 4xGbE BaseT Adapter | 00AG520 | A56M | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
# The maximum quantity shown is with one processor / two processors (this does not apply to ML2 adapters).
† Supported only in the PCIe 3.0 x16 slots supplied by the PCIe x16 riser cards (part numbers 00KA504 and 00KA489).
* The adapter comes without transceivers or cables; for ordering transceivers or cables, see the configuration notes below the table.
‡ Slot 3 is supported only with the PCIe x16 Riser 1 (feature code A5FN). Slot 8 is supported only with the PCIe x16 Riser 2 (feature code A5R5).
§ Not supported with the Intel Xeon processor E5-2600 v3 product family.
Configuration notes:
- ML2 network adapters are supported in the ML2 slot 1 supplied by one of the ML2 Riser Cards (part numbers 00KA504 and 00KA519).
- Unless otherwise specified in the table footnote for the specific adapter, PCIe x8 network adapters are supported in the low profile PCIe x8 slots on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
- PCIe x16 Low Profile network adapters are supported in the full-height PCIe x16 slots supplied by the riser cards 1 and 2.
- Some adapters require supported transceivers or DAC cables to be purchased for the adapter. The maximum number of transceivers or cables that are supported per adapter equals the quantity of the adapter ports, and all adapter ports must have the same type of the transceiver or cable selected.
The following transceiver and cables can be purchased:
- Transceivers and cables for 10 GbE SFP+ adapters
- Transceivers and cables for 25 GbE SFP28 adapters
- Transceivers and cables for 40 GbE QSFP+ adapters
- Cables for Mellanox FDR InfiniBand QSFP adapters
- Transceivers and cables for 100 GbE QSFP28 network adapters
- Cables for Mellanox EDR InfiniBand QSFP28 adapters
- Cables for Intel Omni-Path QSFP28 adapters
The following table lists transceivers and cables for the 10 GbE SFP+ adapters.
Description | Part number | Feature code |
---|---|---|
10 GbE SFP+ SR transceivers for 10 GbE SFP+ adapters | ||
Lenovo 10GBASE-SR SFP+ Transceiver | 46C3447 | 5053 |
Optical cables for 10 GbE SFP+ SR transceivers | ||
Lenovo 0.5m LC-LC OM3 MMF Cable | 00MN499 | ASR5 |
Lenovo 1m LC-LC OM3 MMF Cable | 00MN502 | ASR6 |
Lenovo 3m LC-LC OM3 MMF Cable | 00MN505 | ASR7 |
Lenovo 5m LC-LC OM3 MMF Cable | 00MN508 | ASR8 |
Lenovo 10m LC-LC OM3 MMF Cable | 00MN511 | ASR9 |
Lenovo 15m LC-LC OM3 MMF Cable | 00MN514 | ASRA |
Lenovo 25m LC-LC OM3 MMF Cable | 00MN517 | ASRB |
Lenovo 30m LC-LC OM3 MMF Cable | 00MN520 | ASRC |
Passive SFP+ DAC cables for 10 GbE SFP+ adapters | ||
Lenovo 0.5m Passive SFP+ DAC Cable | 00D6288 | A3RG |
Lenovo 1m Passive SFP+ DAC Cable | 90Y9427 | A1PH |
Lenovo 1.5m Passive SFP+ DAC Cable | 00AY764 | A51N |
Lenovo 2m Passive SFP+ DAC Cable | 00AY765 | A51P |
Lenovo 3m Passive SFP+ DAC Cable | 90Y9430 | A1PJ |
Lenovo 5m Passive SFP+ DAC Cable | 90Y9433 | A1PK |
Lenovo 7m Passive SFP+ DAC Cable | 00D6151 | A3RH |
The following table lists transceivers and cables for the 25 GbE SFP28 adapters.
Description | Part number | Feature code |
---|---|---|
25 GbE SFP28 SR transceivers for 25 GbE SFP+ adapters | ||
Lenovo 25GBase-SR SFP28 Transceiver | 7G17A03537 | AV1B |
Passive copper cables for 25 GbE SFP28 network adapters | ||
Lenovo 1m Passive 25G SFP28 DAC Cable | 7Z57A03557 | AV1W |
Lenovo 3m Passive 25G SFP28 DAC Cable | 7Z57A03558 | AV1X |
Lenovo 5m Passive 25G SFP28 DAC Cable | 7Z57A03559 | AV1Y |
The following table lists transceivers and cables for the 40 GbE QSFP+ adapters.
Description | Part number | Feature code |
---|---|---|
40 GbE QSFP+ transceivers for 40 GbE network adapters | ||
Lenovo 40GBASE-SR4 QSFP+ Transceiver | 49Y7884 | A1DR |
Optical cables for 40 GbE QSFP+ SR4 transceivers | ||
Lenovo 10m QSFP+ MPO-MPO OM3 MMF Cable | 00VX003 | AT2U |
Lenovo 30m QSFP+ MPO-MPO OM3 MMF Cable | 00VX005 | AT2V |
Passive copper cables for 40 GbE QSFP+ network adapters | ||
Lenovo 1m Passive QSFP+ DAC Cable | 49Y7890 | A1DP |
Lenovo 3m Passive QSFP+ DAC Cable | 49Y7891 | A1DQ |
The following table lists cables for the Mellanox FDR InfiniBand QSFP adapters.
Description | Part number | Feature code |
---|---|---|
Passive copper cables for Mellanox FDR InfiniBand QSFP adapters | ||
0.75m Mellanox QSFP Passive DAC Cable | 00KF002 | ARZB |
1m Mellanox QSFP Passive DAC Cable | 00KF003 | ARZC |
1.25m Mellanox QSFP Passive DAC Cable | 00KF004 | ARZD |
1.5m Mellanox QSFP Passive DAC Cable | 00KF005 | ARZE |
3m Mellanox QSFP Passive DAC Cable | 00KF006 | ARZF |
Active optical cables for Mellanox FDR InfiniBand QSFP adapters | ||
3m Mellanox IB FDR Active Optical Fiber Cable | 00KF007 | ARYC |
5m Mellanox IB FDR Active Optical Fiber Cable | 00KF008 | ARYD |
10m Mellanox IB FDR Active Optical Fiber Cable | 00KF009 | ARYE |
15m Mellanox IB FDR Active Optical Fiber Cable | 00KF010 | ARYF |
20m Mellanox IB FDR Active Optical Fiber Cable | 00KF011 | ARYG |
30m Mellanox IB FDR Active Optical Fiber Cable | 00KF012 | ARYH |
The following table lists transceivers and cables for the 100 GbE QSFP28 network adapters.
Description | Part number | Feature code |
---|---|---|
100 GbE QSFP28 transceivers for 100 GbE QSFP28 network adapters | ||
Lenovo 100GBase-SR4 QSFP28 Transceiver | 7G17A03539 | AV1D |
Optical cables for 100 GbE QSFP28 SR4 transceivers | ||
Lenovo 5m MPO-MPO OM4 MMF Cable | 7Z57A03567 | AV25 |
Lenovo 10m MPO-MPO OM4 MMF Cable | 7Z57A03569 | AV27 |
Lenovo 20m MPO-MPO OM4 MMF Cable | 7Z57A03571 | AV29 |
Optical breakout cables for 100 GbE QSFP28 SR4 transceivers | ||
Lenovo 1m MPO-MPO Breakout OM4 MMF Cable | 7Z57A03573 | AV2B |
Lenovo 3m MPO-MPO Breakout OM4 MMF Cable | 7Z57A03574 | AV2C |
Lenovo 5m MPO-MPO Breakout OM4 MMF Cable | 7Z57A03575 | AV2D |
Passive copper cables for 100 GbE QSFP28 network adapters | ||
Lenovo 1m Passive 100G QSFP28 DAC Cable | 7Z57A03561 | AV1Z |
Lenovo 3m Passive 100G QSFP28 DAC Cable | 7Z57A03562 | AV20 |
Lenovo 5m Passive 100G QSFP28 DAC Cable | 7Z57A03563 | AV21 |
Passive copper breakout cables for 100 GbE QSFP28 network adapters | ||
Lenovo 1m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable | 7Z57A03564 | AV22 |
Lenovo 3m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable | 7Z57A03565 | AV23 |
Lenovo 5m 100G QSFP28 to 4x25G SFP28 Breakout DAC Cable | 7Z57A03566 | AV24 |
Active optical cables for 100 GbE QSFP28 network adapters | ||
Lenovo 3m 100G QSFP28 Active Optical Cable | 7Z57A03546 | AV1L |
Lenovo 5m 100G QSFP28 Active Optical Cable | 7Z57A03547 | AV1M |
Lenovo 10m 100G QSFP28 Active Optical Cable | 7Z57A03548 | AV1N |
Lenovo 15m 100G QSFP28 Active Optical Cable | 7Z57A03549 | AV1P |
Lenovo 20m 100G QSFP28 Active Optical Cable | 7Z57A03550 | AV1Q |
The following table lists cables for the Mellanox EDR InfiniBand QSFP28 adapters.
Description | Part number | Feature code |
---|---|---|
Passive copper cables for Mellanox EDR InfiniBand QSFP28 adapters* | ||
0.5m Mellanox EDR IB Passive Copper QSFP28 Cable | 00MP516 | ASQT |
0.75m Mellanox EDR IB Passive Copper QSFP28 Cable | 00MP520 | ASQU |
1m Mellanox EDR IB Passive Copper QSFP28 Cable | 00MP524 | ASQV |
1.25m Mellanox EDR IB Passive Copper QSFP28 Cable | 00MP528 | ASQW |
1.5m Mellanox EDR IB Passive Copper QSFP28 Cable | 00MP532 | ASQX |
2m Mellanox EDR IB Passive Copper QSFP28 Cable | 00MP536 | ASQY |
3m Mellanox EDR IB Passive Copper QSFP28 Cable | 00MP560 | ASRM |
Active optical cables for Mellanox EDR InfiniBand QSFP28 adapters* | ||
3m Mellanox EDR IB Active Optical QSFP28 Cable | 00MP563 | ASRN |
5m Mellanox EDR IB Active Optical QSFP28 Cable | 00MP540 | ASQZ |
10m Mellanox EDR IB Active Optical QSFP28 Cable | 00MP544 | ASR0 |
15m Mellanox EDR IB Active Optical QSFP28 Cable | 00MP548 | ASR1 |
20m Mellanox EDR IB Active Optical QSFP28 Cable | 00MP552 | ASR2 |
30m Mellanox EDR IB Active Optical QSFP28 Cable | 00MP556 | ASR3 |
50m Mellanox EDR IB Active Optical QSFP28 Cable | 00MP566 | ASRP |
* The Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter (00MM960) supports only a subset of the EDR InfiniBand cables listed in the table: 00MP516, 00MP524, 00MP536, and 00MP544.
The following table lists cables for the Intel Omni-Path QSFP28 adapters.
Description | Part number | Feature code |
---|---|---|
Passive copper cables for Intel Omni-Path QSFP28 adapters | ||
0.5m Intel OPA 100 Series Passive Copper QSFP28 Cable | 00WE031 | AU0E |
0.75m Intel OPA 100 Series Passive Copper QSFP28 Cable | 00WE035 | AU0F |
1m Intel OPA 100 Series Passive Copper QSFP28 Cable | 00WE039 | AU0G |
1.25m Intel OPA 100 Series Passive Copper QSFP28 Cable | 00WE043 | AU0H |
1.5m Intel OPA 100 Series Passive Copper QSFP28 Cable | 00WE047 | AU0J |
2m Intel OPA 100 Series Passive Copper QSFP28 Cable | 00WE051 | AU0K |
3m Intel OPA 100 Series Passive Copper QSFP28 Cable | 00WE055 | AU0L |
Active optical cables for Intel Omni-Path QSFP28 adapters | ||
5m Intel OPA 100 Series Active Optical QSFP28 Cable | 00WE059 | AU0M |
10m Intel OPA 100 Series Active Optical QSFP28 Cable | 00WE063 | AU0N |
15m Intel OPA 100 Series Active Optical QSFP28 Cable | 00WE067 | AU0P |
20m Intel OPA 100 Series Active Optical QSFP28 Cable | 00WE071 | AU0Q |
For more information, see the list of Product Guides in the following categories:
- Ethernet Adapters
http://lenovopress.com/servers/options/ethernet?rt=product-guide - InfiniBand / OPA Adapters
http://lenovopress.com/servers/options/infiniband?rt=product-guide
SAS adapters for external storage
The following table lists SAS RAID controllers and HBAs for external storage attachments that are supported by the System x3650 M5 server.
Description | Part number | Feature code | Maximum supported* | I/O slots supported |
---|---|---|---|---|
12 Gbps SAS RAID adapters | ||||
ServeRAID M5225-2GB SAS/SATA Controller | 00AE938 | A5ND | 2 / 3 | 1, 2, 3, 6‡ |
Feature on Demand (FoD) upgrades for the M5225 (one per server)** | ||||
ServeRAID M5200 Series RAID 6 Upgrade | 47C8706 | A3Z5 | 1** | - |
ServeRAID M5200 Series Performance Accelerator | 47C8710 | A3Z7 | 1** | - |
ServeRAID M5200 Series SSD Caching Enabler | 47C8712 | A3Z8 | 1** | - |
12 Gbps SAS HBAs | ||||
N2225 SAS/SATA HBA | 00AE912 | A5M0 | 2 / 5 | 1, 2, 3, 6, 7, 8‡ |
N2226 SAS/SATA HBA | 00AE916 | A5M1 | 2 / 5 | 1, 2, 3, 6, 7, 8‡ |
* The maximum quantity shown is with one processor / two processors.
‡ Slot 3 is supported only with the PCIe x16 Riser 1 (feature code A5FN).
** One FoD upgrade for the M5225 activates the feature on all M5200 series controllers (M5210, M5225) installed in the server.
Configuration note: Unless otherwise specified in the table footnote for the specific adapter, SAS RAID controllers and HBAs are supported in low profile PCIe x8 slots on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
The following table summarizes features of supported RAID controllers and HBAs.
Feature | M5225-2GB | N2226 | N2225 |
Part number | 00AE938 | 00AE916 | 00AE912 |
Form factor | Low profile | Full height | Low profile |
Controller chip | LSI SAS3108 | LSI SAS3008 | LSI SAS3008 |
Host interface | PCIe 3.0 x8 | PCIe 3.0 x8 | PCIe 3.0 x8 |
Port interface | 12 Gbps SAS | 12 Gbps SAS | 12 Gbps SAS |
Number of external ports | 8 | 16 | 8 |
External port connectors | 2x Mini-SAS HD (SFF-8644) |
4x Mini-SAS HD (SFF-8644) |
2x Mini-SAS HD (SFF-8644) |
Drive interface | SAS, SATA | SAS, SATA | SAS, SATA |
Drive type | HDD, SED, SSD | HDD, SSD | HDD, SSD |
Maximum number of devices | 240 | 1024 | 1024 |
RAID levels | 0/1/10/5/50; Optional 6/60 (PN 47C8706) |
None | None |
JBOD mode | No | Yes | Yes |
Cache | 2 GB (included) | None | None |
Cache protection | Flash (included) | None | None |
Performance Accelerator (FastPath) | Optional (PN 47C8710) | None | None |
SSD Caching (CacheCade Pro 2.0) | Optional (PN 47C8712) | None | None |
For more information about the ServeRAID M5225-2GB, see the Lenovo Press Product Guide: http://lenovopress.com/tips1258
For more information about SAS HBAs, see the list of Product Guides in the Host bus adapters category:
https://lenovopress.com/servers/options/hba
Fibre Channel host bus adapters
The following table lists Fibre Channel HBAs supported by the System x3650 M5 server.
Note: FC HBAs are supported in low profile PCIe x8 slots on the system board and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
Description | Part number | Feature code | Maximum supported* | I/O slots supported |
---|---|---|---|---|
16 Gb Fibre Channel - PCIe | ||||
Emulex 16Gb Gen6 FC Single-port HBA | 01CV830 | ATZU | 3 / 7 | 2, 3, 4, 5, 6, 7, 8 |
Emulex 16Gb FC Single-port HBA | 81Y1655 | A2W5 | 3 / 7 | 2, 3, 4, 5, 6, 7, 8 |
Emulex 16Gb Gen6 FC Dual-port HBA | 01CV840 | ATZV | 3 / 7 | 2, 3, 4, 5, 6, 7, 8 |
Emulex 16Gb FC Dual-port HBA | 81Y1662 | A2W6 | 3 / 7 | 2, 3, 4, 5, 6, 7, 8 |
QLogic 16Gb Enhanced Gen5 FC Single-port HBA | 01CV750 | ATZB | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
QLogic 16Gb FC Single-port HBA | 00Y3337 | A3KW | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
QLogic 16Gb Enhanced Gen5 FC Dual-port HBA | 01CV760 | ATZC | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
QLogic 16Gb FC Dual-port HBA | 00Y3341 | A3KX | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
8 Gb Fibre Channel - PCIe | ||||
Emulex 8Gb FC Dual-port HBA | 42D0494 | 3581 | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
Emulex 8Gb FC Single-port HBA | 42D0485 | 3580 | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
QLogic 8Gb FC Dual-port HBA | 42D0510 | 3579 | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
QLogic 8Gb FC Single-port HBA | 42D0501 | 3578 | 4 / 8 | 1, 2, 3, 4, 5, 6, 7, 8 |
* The maximum quantity shown is with one processor / two processors.
For more information, see the list of Product Guides in the Host bus adapters category:
https://lenovopress.com/servers/options/hba
Flash storage adapters
The System x3650 M5 server supports the flash storage adapters listed in the following table.
Note: Flash storage adapters are supported in low profile PCIe x8 slots on the system board (low profile adapters only) and full-high PCIe x8 and x16 slots supplied by the riser cards 1 and 2.
Table 31. Flash storage adapters (LP = Low Profile PCIe adapter, FH = Full-High PCIe adapter)
Description | Part number | Feature code | Maximum supported* | I/O slots supported |
---|---|---|---|---|
Enterprise Performance | ||||
Intel P3700 800GB NVMe AIC | 01GT711 | AVPY | 2 / 5** | 1, 4, 5, 6, 7 |
Intel P3700 1.6TB NVMe Enterprise Performance Flash Adapter (LP) | 00YA812 | AT7L | 2 / 5 | 1, 4, 5, 6, 7 |
Intel P3700 2.0TB NVMe Enterprise Performance Flash Adapter (LP) | 00YA815 | AT7M | 2 / 5 | 1, 4, 5, 6, 7 |
Enterprise Mainstream | ||||
io3 1.25TB Enterprise Mainstream Flash Adapter (LP) | 00YA800 | AT7N | 2 / 5 | 1, 4, 5, 6, 7 |
io3 1.6TB Enterprise Mainstream Flash Adapter (LP) | 00YA803 | AT7P | 2 / 5 | 1, 4, 5, 6, 7 |
1.92TB NVMe Enterprise Mainstream Flash Adapter (LP) | 00YK286 | AVP3 | 2 / 5** | 1, 4, 5, 6, 7 |
3.84TB NVMe Enterprise Mainstream Flash Adapter (LP) | 00YK287 | AVP4 | 2 / 5** | 1, 4, 5, 6, 7 |
io3 6.4TB Enterprise Mainstream Flash Adapter (FH) | 00YA809 | AT7R | 3 / 6 | 1, 2, 3, 6, 7, 8 |
Enterprise | ||||
1000GB Enterprise io3 Flash Adapter (LP) | 00AE995 | ARYP | 2 / 5 | 1, 4, 5, 6, 7 |
1300GB Enterprise io3 Flash Adapter (LP) | 00AE998 | ARYQ | 2 / 5 | 1, 4, 5, 6, 7 |
2600GB Enterprise io3 Flash Adapter (LP) | 00JY001 | ARYR | 2 / 5 | 1, 4, 5, 6, 7 |
* The maximum quantity shown is with one processor / two processors.
** Not supported with the Intel Xeon processor E5-2600 v3 product family.
Configuration notes:
- With 3.5-inch drive bay models, the Flash Adapters are supported only in the environments with the air temperature of up to 30 °C (86 °F).
- The io3 Flash Adapters cannot be factory installed; they are supported as field-installable options only. The server cannot be shipped with these adapters installed.
For more information, see the list of Product Guides in the Flash storage adapters category:
http://lenovopress.com/servers/options/ssdadapter
GPU adapters
The System x3650 M5 server supports graphics processing units (GPUs) listed in the following table.
Description | Part number | Feature code | Maximum supported** | I/O slots supported |
---|---|---|---|---|
Full-high PCIe x16 adapters (x16-wired) | ||||
NVIDIA Grid K1 (Actively Cooled) | 00YL374 | AS3G | 1 / 2 | 1, 6 |
NVIDIA Quadro K6000 | None* | A3YV | 1 / 2 | 1, 6 |
NVidia Quadro M5000 GPU, PCIe (active) | 00YL378 | ATZF | 1 / 2 | 1, 6 |
NVidia Quadro M6000 24GB GPU, PCIe (active) | 90Y2495 | AU3W | 1 / 2 | 1, 6 |
NVIDIA Tesla K40c | 00YL376 | A5FG | 1 / 2 | 1, 6 |
NVIDIA Tesla M10 GPU, PCIe (passive) | 7C57A02891 | AX8L | 1 / 2*** | 1, 6 |
NVidia Tesla M60 GPU, PCIe (active) | 00YL377 | ASQL | 1 / 2 | 1, 6 |
NVIDIA Tesla P40 GPU, PCIe (passive) | 7C57A02888 | AVNZ | 1 / 2*** | 1, 6 |
NVIDIA Tesla P100 PCIe 16GB (passive) | 7X67A00068 | AUV5 | 1 / 2*** | 1, 6 |
Full-high PCIe x16 adapters (x8-wired) | ||||
NVIDIA Quadro K420 | 00YL370 | ASPN | 2 / 4 | 1, 2, 6, 7 |
NVIDIA Quadro K620 | 00YL371 | ASPP | 2 / 4 | 1, 2, 6, 7 |
NVIDIA Quadro K2200 | 00YL372 | ASQM | 2 / 4 | 1, 2, 6, 7 |
* These GPU adapters are available only through Special Bid or CTO.
** The maximum quantity shown is with one processor / two processors.
*** Not supported with the Intel Xeon processor E5-2600 v3 product family.
Configuration notes:
- The NVIDIA PCIe x16 adapters (x16-wired) require PCIe x16 riser cards.
- The NVIDIA PCIe x16 adapters (x8-wired) are supported with PCIe x8 or PCIe x16 riser cards, or a combination of PCIe x8 and PCIe x16 riser cards (with PCIe x16 riser cards, slots 2 [Riser 1] and 7 [Riser 2] are not available).
- All GPUs installed in the server must be the same.
- The maximum memory that can be installed is 1 TB.
- Each M6000 GPU requires at least 48 GB of memory.
- The GPU adapters are supported only in the environments with the air temperature of up to 35 °C (95 °F).
- Passively cooled GPU adapters (part numbers 7C57A02891, 7C57A02888, and 7X67A00068) require the dual-rotor fans (included in a dual-rotor fan CTO base or in the optional x3650 M5 Dual Rotor Fan Thermal Kit [part number 00YD003]) and the optional x3650 M5 Passive GPU Thermal Kit (part number 01GV396).
- Further restrictions may apply depending on the power supplies installed (see Power supplies and cables).
Cooling
The System x3650 M5 server supports up to six system fans that provide dual fan zones cooling with N+1 fan
redundancy, and each system fan has one or two rotors depending on the model. System x3650 M5 servers with single-rotor fans can be upgraded to dual-rotor fan systems by replacing the existing single-rotor fans and cage with the dual-rotor fans and cage by using the optional Dual Rotor Fan Thermal Kit (part number 00YD003).
Single rotor fan-based server models of the System x3650 M5 with one processor include four system fans, and server models with two processors include six system fans. Dual-rotor fan server models of the System x3650 M5 include six system fans.
The following table shows additional cooling options.
Description | Part number | Feature code | Maximum supported |
---|---|---|---|
System x3650 M5 PCIe Thermal Solution Kit | 00MU908 | ASQD | 1 |
System x3650 M5 Dual Rotor Fan Thermal Kit | 00YD003 | None | 1 |
System x3650 M5 Passive GPU Thermal Kit | 01GV396 | None | 1 |
Configuration notes:
- The PCIe thermal solution kit (part number 00MU908) is required if any of the ML2 adapters are present in the configuration. The PCIe thermal kit contains an air baffle.
- The Passive GPU Thermal Kit (part number 01GV396) is required when passively cooled GPU adapters (part numbers 7C57A02891, 7C57A02888, and 7X67A00068) are present in the configuration. The Passive GPU Thermal Kit contains an air duct, two low-profile heatsinks, four GPU power cables, and a full-length card holder.
- The Dual Rotor Fan Thermal Kit (part number 00YD003) is required for single-rotor fan server models of the System x3650 M5 when passively cooled GPU adapters (part numbers 7C57A02891, 7C57A02888, and 7X67A00068) are present in the configuration. The Dual Rotor Fan Thermal Kit contains six dual-rotor fans and a fan cage.
Power supplies and cables
The System x3650 M5 server supports up to two redundant power supplies, and is capable of N+N redundancy depending on the configuration. Standard models come with one power supply. The following table lists the power supply options.
Description | Part number | Feature code | Maximum supported |
System x 550W High Efficiency Platinum AC Power Supply | 00FK930 | A5ET | 2 |
System x 750W High Efficiency Platinum AC Power Supply | 00FK932 | A5EU | 2 |
System x 750W High Efficiency Titanium AC Power Supply (200-240V) | 00FK934 | A5EV | 2 |
System x 900W High Efficiency Platinum AC Power Supply | 00FK936 | A5EW | 2 |
System x 900W High Efficiency -48 V DC Power Supply | 00MU910 | ASQF | 2 |
System x 1300W High Efficiency Titanium AC Power Supply (200-240V) | 00MU911 | ASQG | 2 |
System x 1500W High Efficiency Platinum AC Power Supply (200-240V) | 00MU909 | ASQE | 2 |
General power supply rules are as follows:
- Minimum of 1 and maximum of 2 power supplies per system.
- If 2 are installed, power supplies must be identical.
Important: The Standalone Solution Configuration Tool (SSCT) and Lenovo Data Center Advisor and Configurator Tool (DCACT) power supply selection rules allow a subset of possible configurations due to power restrictions. Configurations that cannot be built in SSCT or DCACT due to power restrictions may still be supported. To verify support and ensure that the right power supply is chosen for optimal performance, you should always validate your server configuration using the latest version of the System x Power Configurator:
https://support.lenovo.com/documents/LNVO-PWRCONF
The System x3650 M5 servers ship standard with or without a power cord (model dependent). The 900 W AC power supply option ships with one 2.8m, 13A/125V-10A/250V, IEC 320-C13 to C14 rack power cable (feature code 6400), and the other hot-swap AC power supply options ship standard with one 2.8m, 10A/100-250V, IEC 320-C13 to C14 rack power cable (feature code 6311).
Description | Part number | Feature code |
---|---|---|
Rack power cables | ||
1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7937 | 6201 |
2.0m, 10A/125-250V, C13 to IEC 320-C14 Rack Power Cable | None* | 6316 |
2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | None* | 6311 |
2.8m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable | None* | 6400 |
2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable | 39Y7938 | 6204 |
4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable | 39Y7932 | 6263 |
Country-specific line cords | ||
Argentina 10A/250V C13 to IRAM 2073 2.8m line cord | 39Y7930 | 6222 |
Australia/NZ 10A/250V C13 to AS/NZ 3112 2.8m line cord | 39Y7924 | 6211 |
Brazil 10A/125V C13 to 2P+Gnd 1.8m line cord | None* | 6599 |
Brazil 10A/250V C13 to 2P+Gnd 1.8m line cord | None* | 6364 |
Brazil 10A/125V C13 to NBR 6147 2.8m line cord | 39Y7929 | 6223 |
Brazil 10A/250V C13 to NBR 14136 2.8m line cord | 69Y1988 | 6532 |
China 10A/250V C13 to GB 2099.1 2.8m line cord | 39Y7928 | 6210 |
Denmark 10A/250V C13 to DK2-5a 2.8m line cord | 39Y7918 | 6213 |
Europe 10A/230V C13 to CEE7-VII 2.8m line cord | 39Y7917 | 6212 |
Europe 10A/250V, C13 to IEC 309 2P+Gnd 2.8m line cord | None* | 6377 |
Europe 10A/250V C13 to 2P+Gnd 4.3m line cord | None* | 6374 |
India 10A/250V C13 to IS 6538 2.8m line cord | 39Y7927 | 6269 |
Israel 10A/250V C13 to SI 32 2.8m line cord | 39Y7920 | 6218 |
Italy 10A/250V C13 to CEI 23-16 2.8m line cord | 39Y7921 | 6217 |
Japan 12A/125V C13 to JIS C-8303 2.8m line cord | 46M2593 | A1RE |
Korea 12A/250V C13 to KETI 2.8m line cord | 39Y7925 | 6219 |
South Africa 10A/250V C13 to SABS 164 2.8m line cord | 39Y7922 | 6214 |
Switzerland 10A/250V C13 to SEV 1011-S24507 2.8m line cord | 39Y7919 | 6216 |
Taiwan 10A/125V C13 to CNS 10917-3 1.8m line cord | None* | 6526 |
Taiwan 10A/250V C13 to CNS 10917-3 2.8m line cord | 00CG265 | 6317 |
Taiwan 15A/125V C13 to CNS 10917-3 2.8m line cord | 00CG267 | 6386 |
United Kingdom 10A/250V C13 to BS 1363/A 2.8m line cord | 39Y7923 | 6215 |
United States 10A/125V C13 to NEMA 5-15P 1.8m line cord | None* | 6369 |
United States 10A/120V C13 to NEMA 5-15P 2.8m line cord | 90Y3016 | 6313 |
United States 10A/125V C13 to NEMA 5-15P 4.3m line cord | 39Y7931 | 6207 |
United States 10A/250V C13 to NEMA 6-15P 1.8m line cord | None* | 6351 |
United States 10A/250V C13 to NEMA 6-15P 2.8m line cord | 46M2592 | A1RF |
* Available via Configure to Order (CTO).
Configuration note: If the 900 W AC power supplies (00FK936) in the System x3650 M5 server are connected to a low-voltage power source (100 - 125 V), the only supported power cables are those that are rated above 10A; cables that are rated at 10A are not supported.
Integrated virtualization
The System x3650 M5 server supports VMware ESXi installed on a USB memory key or one or two SD cards in the SD Media Adapter. The USB memory key is installed in a USB socket inside the server. The SD Media Adapter is installed in a dedicated slot inside the server.
When only one SD card is installed in the SD Media Adapter, you can create up to 16 volumes, each of which is presented to UEFI as a bootable device. When two SD Media cards are inserted, volumes can be mirrored (RAID 1) across both cards, up to a total of eight mirrored volumes. The RAID functionality is handled internally by the SD Media Adapter.
The following table lists the virtualization option.
Description | Part number | Feature code | Maximum supported |
USB memory key | |||
USB Memory Key for VMware ESXi 5.1 Update 2 | 00ML233 | ASN6 | 1 |
USB Memory Key for VMware ESXi 5.5 Update 2 | 00ML235 | ASN7 | 1 |
USB Memory Key for VMware ESXi 5.5 Update 3B | 00WH150 | ATZG | 1 |
USB Memory Key 4G for VMware ESXi 6.0 Update 1A | 00WH138 | ATRL | 1 |
USB Memory Key for VMware ESXi 6.0 Update 2 | 00WH151 | ATZH | 1 |
USB Memory Key for VMware ESXi 6.5 | None** | AVNW | 1 |
Blank USB Memory Key 4G SLC for VMware ESXi Downloads | 00WH140 | ATRM | 1 |
Blank USB Memory Key for VMware ESXi Downloads | 41Y8298 | A2G0 | 1 |
SD Media Adapter and SD cards | |||
SD Media Adapter (Option 00ML706 includes 2 blank 32GB SD cards) | 00ML706* | A5TJ | 1 |
Blank SD Media for System x | 00ML700 | AS2V | 2 |
RAID Adapter for SD Media w/ VMware ESXi 5.1 U2 (2 SD Media, RAIDed) | None** | AS4B | 1 |
RAID Adapter for SD Media w/ VMware ESXi 5.5 U2 (2 SD Media, RAIDed) | None** | AS4C | 1 |
RAID Adapter for SD Media w/ VMware ESXi 5.1 U2 (1 SD Media) | None** | ASCG | 1 |
RAID Adapter for SD Media w/ VMware ESXi 5.5 U2 (1 SD Media) | None** | ASCH | 1 |
RAID Adapter for SD Media w/ VMware ESXi 5.5 U3B (1 SD Media) | None** | ATZK | 1 |
RAID Adapter for SD Media w/ VMware ESXi 5.5 U3B (2 SD Media, RAIDed) | None** | ATZJ | 1 |
RAID Adapter for SD Media w/VMware ESXi 6.0 U1A (1 SD Media) | None** | ATSA | 1 |
RAID Adapter for SD Media w/VMware ESXi 6.0 U1A (2 SD Media, RAIDed) | None** | ATS9 | 1 |
RAID Adapter for SD Media w/ VMware ESXi 6.0 U2 (1 SD Media) | None** | ATZM | 1 |
RAID Adapter for SD Media w/ VMware ESXi 6.0 U2 (2 SD Media, RAIDed) | None** | ATZL | 1 |
Adapter for SD Media w/ VMware ESXi 6.5 (1 SD Media) | None** | AVNX | 1 |
Adapter for SD Media w/ VMware ESXi 6.5 (2 SD Media, RAIDed) | None** | AVNY | 1 |
* Option 00ML706 includes two 32GB SD cards; however, for CTO orders, feature code A5TJ does not include SD media and the 32 GB cards and VMware vSphere preload must be selected separately.
** CTO only.
Operating systems
The System x3650 M5 server supports the following operating systems:
- Microsoft:
- Microsoft Windows Server 2016
- Microsoft Windows Server 2012 R2
- Microsoft Windows Server 2012
- Microsoft Windows Server 2008 R2 SP1
- Red Hat:
- Red Hat Enterprise Linux 7.3
- Red Hat Enterprise Linux 7.2
- Red Hat Enterprise Linux 6.8 Server x64 Edition
- Red Hat Enterprise Linux 6.7 Server x64 Edition
- SUSE:
- SUSE Linux Enterprise Server 12 SP2
- SUSE Linux Enterprise Server with Xen 12 SP2
- SUSE Linux Enterprise Server 12 SP1
- SUSE Linux Enterprise Server with Xen 12 SP1
- SUSE Linux Enterprise Server 11 for AMD64/EM64T SP4
- SUSE Linux Enterprise Server 11 with Xen for AMD64/EM64T SP4
- VMware:
- VMware vSphere 6.5 (ESXi)
- VMware vSphere 6.0 (ESXi) Update 3
- VMware vSphere 6.0 (ESXi) Update 2
- VMware vSphere 5.5 (ESXi) Update 3
For the latest information about the specific versions and service levels that are supported and any other prerequisites, see the Operating System Interoperability Guide: http://lenovopress.com/redposig.
Systems management
The System x3650 M5 supports the following systems management tools:
- Integrated Management Module 2.1
- Light path diagnostics
- Lenovo ToolsCenter
- Lenovo XClarity Administrator
- Lenovo XClarity Energy Manager
Integrated Management Module 2.1
The System x3650 M5 server contains Integrated Management Module II (IMM2.1), which provides advanced service-processor control, monitoring, and an alerting function. If an environmental condition exceeds a threshold or if a system component fails, the IMM2.1 lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. Optionally, the IMM2.1 also provides a virtual presence capability for remote server management capabilities.
The IMM2.1 provides remote server management through industry-standard interfaces:
- Intelligent Platform Management Interface (IPMI) Version 2.0
- Simple Network Management Protocol (SNMP) Version 3
- Common Information Model (CIM)
- Web browser
The optional Integrated Management Module Advanced Upgrade is required to enable the remote presence and blue-screen capture features. The remote presence feature provides the following functions:
- Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel
- Remotely accessing the server using the keyboard and mouse from a remote client
- Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives that are available for use by the server
- Uploading a diskette image to the IMM memory and mapping it to the server as a virtual drive
The blue-screen capture feature captures the video display contents before the IMM2.1 restarts the server when the IMM2.1 detects an operating system hang condition. A system administrator can use the blue-screen capture to assist in determining the cause of the hang condition.
The following table lists the remote management option.
Description | Part number | Feature code | Maximum supported |
Integrated Management Module Advanced Upgrade | 90Y3901 | A1ML | 1 |
Light path diagnostics
All System x3650 M5 server models include basic light path diagnostics, which provides the system LEDs on the front of the server (see Components and connectors) and the LEDs near the monitored components (for example, the DIMM error LED on the system board).
Server models with 8x 3.5-inch or 8x or 16x 2.5-inch front drive bays support a next-gen light path diagnostics LCD display panel (standard on 8x 3.5-inch models; available as an option for 8x or 16x 2.5-inch models). With LCD display, you have quick access to system status, firmware, network, and health information.
Storage dense server models (models with USB ports and system LEDs that are located on the right EIA bracket) with 8x or 16x 2.5-inch front drive bays that are upgradeable to 24x 2.5-inch front drive bays and models with 12x 3.5-inch front drive bays do not support an LCD display panel.
The following table shows the LCD display panel ordering information.
Description | Part number | Feature code | Maximum supported |
x3650 M5 Front IO Cage Adv. (3x USB, LCD, Optional Optical Drive) | 00YD002* | None* | 1 |
* The Front IO Cage Advanced part number (00YD002) includes the Front IO Cage Standard (feature code ATE6), System x3650 M5 2.5" Bezel with LCD Light Path (feature code ATE8), and LCD display (feature code A4VH). If configured via CTO, the LCD display (feature code A4VH) is derived when the Front IO Cage Standard (feature code ATE6) and System x3650 M5 2.5" Bezel with LCD Light Path (feature code ATE8) are selected.
Lenovo ToolsCenter
Lenovo offers the following ToolsCenter software tools that can help you set up, use, and maintain the server at no additional cost:
- Lenovo ToolsCenter Suite
The ToolsCenter Suite tool is a consolidation of server management tools that helps simplify the management of System x servers. It provides functions to collect full system health information (including health status), configure system setting, update system firmware and drivers, and FoD mass activation key management for multiple endpoints.
- Lenovo ServerGuide
The ServerGuide tool simplifies the process of configuring RAID and installing supported Microsoft Windows Server operating systems and device drivers on a System x server.
- Lenovo UpdateXpress System Packs
The UpdateXpress System Packs (UXSPs) are integration-tested bundles that enable you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages.
- Lenovo Dynamic System Analysis
The Dynamic System Analysis (DSA) pre-boot or standalone diagnostics software speeds up troubleshooting tasks to reduce service time.
For more information and downloads, visit the ToolsCenter web page:
http://support.lenovo.com/us/en/documents/LNVO-center
Lenovo XClarity Administrator
Lenovo XClarity is a centralized systems management solution that helps administrators deliver infrastructure faster. This solution integrates easily with Lenovo x86 rack servers, Flex System, and RackSwitch switches, providing automated agent-less discovery, monitoring, firmware updates, configuration management, and bare metal deployment of operating systems and hypervisors across multiple systems.
Lenovo XClarity Administrator is an optional software component for the System x3650 M5 which can be downloaded and used at no charge to discover and monitor the x3650 M5 and manage firmware upgrades for them.
If software support is required for Lenovo XClarity Administrator, or Lenovo XClarity Administrator premium features (such as configuration management and operating system deployment) are required, or both, Lenovo XClarity Pro software subscription should be ordered. Lenovo XClarity Pro is licensed on a per managed system basis, that is, each managed Lenovo system requires a license.
The following table lists the geo-specific Lenovo XClarity software license options.
Description | Part number (NA, AP, Japan)* |
Part number (EMEA, LA)** |
Quantity |
Lenovo XClarity Pro, per Mngd Server w/1 Yr SW S&S | 00MT201 | 00MT207 | 1 |
Lenovo XClarity Pro, per Mngd Server w/3 Yr SW S&S | 00MT202 | 00MT208 | 1 |
Lenovo XClarity Pro, per Mngd Server w/5 Yr SW S&S | 00MT203 | 00MT209 | 1 |
* NA = North America; AP = Asia Pacific
** EMEA = Europe, Middle East, Africa; LA = Latin America
Lenovo XClarity Administrator offers the following standard features that are available at no charge:
- Auto-discovery and monitoring of Lenovo x86 servers, RackSwitch switches, and Flex System chassis
- Firmware updates and compliance enforcement
- External alerts and notifications via SNMP traps, syslog remote logging, and e-mail
- Secure connections to managed endpoints
- NIST 800-131A or FIPS 140-2 compliant cryptographic standards between the management solution and managed endpoints
- Integration into existing higher level management systems such as cloud automation and orchestration tools through REST APIs, providing extensive external visibility and control over hardware resources
- An intuitive, easy-to-use GUI
- Scripting with Windows PowerShell, providing command-line visibility and control over hardware resources
Lenovo XClarity Administrator offers the following premium features that require an optional Pro license:
- Pattern-based configuration management that allows to define configurations once and apply repeatedly without errors when deploying new servers or redeploying existing servers without disrupting the fabric
- Bare-metal deployment of operating systems and hypervisors to streamline infrastructure provisioning
In addition, Lenovo XClarity Administrator offers two software plug-in modules (Lenovo XClarity Integrators) at no charge (if software support is required, a Lenovo XClarity Pro software subscription license should be ordered):
- Lenovo XClarity Integrator for Microsoft System Center
- Lenovo XClarity Integrator for VMware vCenter
Lenovo XClarity Integrators allow administrators to manage physical infrastructure from leading external virtualization management software tools from Microsoft and VMware. Lenovo XClarity Integrators offer the following additional features:
- Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
- Deployment of firmware updates and configuration patterns to System x M5, M6, and X6 rack servers and Flex System from the virtualization management tool
- Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
- Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted
For more information, refer to the Lenovo XClarity Administrator Product Guide:
http://lenovopress.com/tips1200
Lenovo XClarity Energy Manager
Lenovo XClarity Energy Manager provides a stand-alone, web-based agent-less power management console that provides real time data and enables you to observe, plan and manage power and cooling for Lenovo System x and ThinkServer x86 servers. Using built-in intelligence, it identifies server power consumption trends and ideal power settings and performs cooling analysis so that you can define and optimize power-saving policies.
Lenovo XClarity Energy Manager offers the following capabilities:
- Reports vital server information, such as power, temperature and resource utilization
- Monitors inlet temperature to locate hot spots, reducing the risk of data or device damage
- Provides finely-grained controls to limit platform power in compliance with IT policy
- Generates alerts when a user-defined threshold is reached
Lenovo XClarity Energy Manager is an optional software component for the System x3650 M5 that is licensed on a per managed node basis, that is, each managed server requires a license.
The following table lists the geo-specific Lenovo XClarity Energy Manager software license options.
Description | Part number (NA, AP, Japan)* |
Part number (EMEA, LA)** |
Quantity |
Lenovo XClarity Energy Manager, 1 Node w/ 1 Yr S&S | 01DA225 | 01DA228 | 1 |
Lenovo XClarity Energy Manager, 5 Nodes w/ 1 Yr S&S | 01DA226 | 01DA229 | 1 |
Lenovo XClarity Energy Manager, 50 Nodes w/ 1 Yr S&S | 01DA227 | 01DA230 | 1 |
* NA = North America; AP = Asia Pacific
** EMEA = Europe, Middle East, Africa; LA = Latin America
Rack installation
The following table lists the rack installation options that are available for the System x3650 M5 server.
Description | Part number | Feature code | Maximum supported |
4-post rail kits | |||
System x Enterprise Slides Kit | 00FK656 | A5FV | 1 |
System x Gen-II Universal Slides Kit | 00KA500 | A5FW | 1 |
System x M5 Custom Rail Kit | 00MW239 | ATLQ | 1 |
Cable management arm (CMA) | |||
System x Enterprise 2U Cable Management Arm (CMA) | 00FK622 | A5FX | 1* |
Lockable front bezel | |||
System x3650 M5 Lockable Bezel | 00FK660 | A5G0 | 1 |
Front VGA port | |||
System x3650 M5 EIA L - VGA | 00YD071 | ATE9 | 1 |
* The System x CMA requires the Enterprise Slides Kit (00FK656) or Universal Slides Kit (00KA500). The Custom Rail Kit (00MW239) is not supported with the CMA.
Note: The System x Enterprise Slides Kit, part number 00FK656, is included with the standard models that are listed in Table 2 and TopSeller models that are listed in Table 3.
The following table summarizes the rail kit features and specifications.
Feature | System x Enterprise Slides Kit | System x Gen-II Universal Slides Kit | System x M5 Custom Rail Kit |
---|---|---|---|
Part number | 00FK656 | 00KA500 | 00MW239 |
Rail type | Full-out slide (ball bearing) | Full-out slide (ball bearing) | Half-out slide (friction) |
Toolless installation | Yes | No | Yes |
CMA support | Yes | Yes | No |
In-rack server maintenance | Yes | Yes | No |
1U PDU support | Yes | Yes | Yes |
0U PDU support | Limited* | Limited* | Limited** |
Rack type | IBM and Lenovo 4-post, IEC standard-compliant |
Any 4-post, IEC standard-compliant |
IBM and Lenovo 4-post, IEC standard-compliant |
Mounting holes | Square or round | Square, round, or threaded | Square or round |
Mounting flange thickness | 2 mm (0.08 in.) – 3.3 mm (0.13 in.) |
2 mm (0.08 in.) – 4.65 mm (0.18 in.) |
2 mm (0.08 in.) – 4 mm (0.16 in.) |
Distance between front and rear mounting flanges |
617 mm (24.29 in.) – 812 mm (31.97 in.) |
617 mm (24.29 in.) – 812 mm (31.97 in.) |
595 mm (23.43 in.) – 746 mm (29.37 in.) |
Rail length*** | 833.5 mm (32.81 in.) | 836.8 mm (32.94 in.) | 755 mm (29.72 in.) |
* The rack must be at least 1100 mm (43.31 in.) deep if no CMA is used, or at least 1200 mm (47.24 in.) deep if a CMA is used.
** The rack must be at least 1000 mm (39.37 in.) deep.
*** Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail.
Physical specifications
The System x3650 M5 server has the following dimensions and weight (approximate):
- Height: 87 mm (3.4 in.)
- Width: 434 mm (17.1 in.)
- Depth: 755 mm (29.7 in.)
- Weight:
- Minimum configuration: 19 kg (41.8 lb)
- Maximum configuration: 34 kg (74.8 lb)
Operating environment
The System x3650 M5 server is supported in the following environment:
- Air temperature:
- Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 to 950 m (3,117 ft); decrease the maximum system temperature by 1 °C for every 175-m increase in altitude above 950 m.
- Server off: 5 °C to 45 °C (41 °F to 113 °F)
- Maximum altitude: 3,050 m (10,000 ft), 5 °C to 28 °C (41 °F to 82 °F)
- Shipment: -40 °C to +60 °C (-40 °F to 140 °F) at up to 10,700 m (35,105 ft)
- Humidity:
- Server on: 8% to 85% (non-condensing), max dew point 24 °C, max rate of change 5 °C/hr
- Server off: 8% to 85% (non-condensing), max dew point 27 °C
- Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
- Supports cloud-like workload with no performance degradation acceptable (Turbo-Off).
- Under no circumstance can any combination of worst-case workload and configuration result in system shutdown or design exposure at 40 °C.
- The worst-case workload (like Linpack, Turbo-On) might have performance degradation.
- Electrical:
- Models with 1500 W Platinum power supplies:
- 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 8.35 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.15 kVA
- Maximum configuration: 1.967 kVA
- Models with 1300 W Titanium power supplies:
- 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 7.137 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.15 kVA
- Maximum configuration: 1.700 kVA
- Models with 900 W AC power supplies:
- 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 10.3 A
- 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 5.0 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.15 kVA
- Maximum configuration: 1.194 kVA
- Models with 750 W Platinum AC power supplies:
- 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 8.6 A
- 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.15 kVA
- Maximum configuration: 1.015 kVA
- Models with 750 W Titanium AC power supplies:
- 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.2 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.15 kVA
- Maximum configuration: 0.965 kVA
- Models with 550 W AC power supplies:
- 100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 6.5 A
- 200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.3 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.16 kVA
- Maximum configuration: 0.732 kVA
- Models with -48Vdc 900 W power supplies:
- -48 - -60 (nominal) V dc; 25.8 A
- Input kilovolt-amperes (kVA) (approximately):
- Minimum configuration: 0.15 kVA
- Maximum configuration: 1.237 kVA
- Models with 1500 W Platinum power supplies:
- BTU output:
- Minimum configuration: 525 Btu/hr (154 watts)
- Maximum configuration: 6667 Btu/hr (1954 watts)
- Acoustics:
- 6.6 bels (operating)
- 6.4 bels (idle)
- Vibration:
- Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
- Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
- Shock:
- Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
- Non-operating:
- 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
- 23 kg - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces
Warranty
The System x3650 M5 has a three-year customer-replaceable unit (CRU) and onsite (for field-replaceable units [FRUs] only) limited warranty with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered. Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.
Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For more information about Lenovo warranty service upgrade offerings that are available in your country, refer to the Lenovo Enterprise Solutions Configurator (LESC):
http://lesc.lenovo.com
The following table explains warranty service definitions in more detail.
Term | Description |
---|---|
Onsite Service | If a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location. |
Parts Delivered | If a problem with your product cannot be resolved via telephone and a CRU part is required, Lenovo will send a replacement CRU to arrive at your location. If a problem with your product cannot be resolved via telephone and a FRU part is required, a Service Technician will be dispatched to arrive at your location. |
Technician Installed Parts | If a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location. |
Hours of coverage |
|
Response time target | 2 hours, 4 hours, or Next Business Day: The time period from when the telephone based troubleshooting is completed and logged, to the delivery of the CRU or arrival of a Service Technician and part at the Customer’s location for repair. |
Committed Repair | 6 hours: The time period between the service request registration in Lenovo’s call management system and the restoration of the product to conformance with its specification by a Service Technician. |
The following Lenovo warranty service upgrades are available:
- Warranty and maintenance service upgrades:
- Three, four, or five years of 9x5 or 24x7 service coverage
- Parts delivered or technician installed parts from next business day to 4 or 2 hours
- Committed repair service
- Warranty extension of up to 5 years
- Post warranty extensions
- Committed Service Repair
Committed Service Repair (CSR) enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.
- Priority handling to meet defined time frames to restore the failing machine to good working condition
- 24x7x6 committed repair: Service performed 24 hours per day, 7 days per week, within 6 hours
- YourDrive YourData
Lenovo’s YourDrive YourData service is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles with Lenovo warranty upgrades and extensions.
- Microcode Support
Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by country and can be bundled with other warranty upgrades and extensions.
- Enterprise Software Support
Lenovo Enterprise Server Software Support can help you troubleshoot your entire server software stack. Choose support for server operating systems from Microsoft, Red Hat, SUSE, and VMware; Microsoft server applications; or both operating systems and applications. Support staff can help answer troubleshooting and diagnostic questions, address product compatibility and interoperability issues, isolate causes of problems, report defects to software vendors, and more.
In addition, you can access hardware “how to” support for System x servers. Staff can help resolve hardware problems not covered under warranty, refer you to the right documentation and publications, provide corrective service information for known defects, and transfer you to a hardware support call center if needed.
- Hardware Installation Services
Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities. Your new systems will be configured and ready for your software installation.
Regulatory compliance
The server conforms to the following regulations:
- FCC - Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, issue 5, Class A
- UL/IEC 60950-1
- CSA C22.2 No. 60950-1
- NOM-019
- Argentina IEC60950-1
- Japan VCCI, Class A
- Australia/New Zealand AS/NZS CISPR 22, Class A; AS/NZS 60950.1
- China CCC GB4943.1, GB9254 Class A, GB17625.1
- India IS 13252 (Part 1)
- Taiwan BSMI CNS13438, Class A; CNS14336-1
- Korea KN22, Class A; KN24
- Russia, Belorussia and Kazakhstan, TR CU 020/2011 (for EMC) and TR CU 004/2011 (for safety)
- IEC 60950-1 (CB Certificate and CB Test Report)
- CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
- CISPR 22, Class A
- TUV-GS (EN60950-1 /IEC60950-1,EK1-ITB2000)
- RoHS Directive
- Energy Star 2.1
External drive enclosures
The following table lists the 6 Gbps SAS external drive enclosures that are offered by Lenovo that can be used with the System x3650 M5 for storage expansion.
Description | Part number |
---|---|
Lenovo Storage E1012 LFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD | 64111B1 |
Lenovo Storage E1012 LFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD | 64111B2 |
Lenovo Storage E1024 SFF Disk Expansion Single SAS IO Module, Rail Kit, 9x5 NBD | 64111B3 |
Lenovo Storage E1024 SFF Disk Expansion Dual SAS IO Module, Rail Kit, 9x5 NBD | 64111B4 |
For details about supported drives, adapters, and cables for the Lenovo Storage E1012 and E1024, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0043
The following table lists the relationship models of the 12 Gbps SAS external drive enclosures that are offered by Lenovo that can be used with the System x3650 M5 for storage expansion.
Description | Part number |
---|---|
LFF models | |
D1212 LFF Chassis, Dual 3-port ESMs (US English documentation) | 4587A11* |
D1212 LFF Chassis, Dual 3-port ESMs (Simplified Chinese documentation) | 4587A1C^ |
D1212 LFF Chassis, Dual 3-port ESMs (Japanese documentation) | 4587A1J** |
SFF models | |
D1224 SFF Chassis, Dual 3-port ESMs (US English documentation) | 4587A31* |
D1224 SFF Chassis, Dual 3-port ESMs (Simplified Chinese documentation) | 4587A3C^ |
D1224 SFF Chassis, Dual 3-port ESMs (Japanese documentation) | 4587A3J** |
* Available worldwide (except China and Japan)
^ Available only in China
** Available only in Japan
The following table lists the TopSeller models of the 12 Gbps SAS external drive enclosures that are offered by Lenovo that can be used with the System x3650 M5 for storage expansion.
Description | Part number |
---|---|
LFF models - North America (NA) and Europe, Middle East, and Africa (EMEA) | |
Lenovo Storage D1212 LFF Dual ESM Disk Expansion Enclosure (US English documentation) | 4587E11 |
LFF models - Brazil and Latin America | |
D1212 LFF Chassis, Dual 3-port ESMs, 4x 2TB 3.5" HDDs, 4x 0.5m SAS cables | 4587EAU |
D1212 LFF Chassis, Dual 3-port ESMs, 4x 4TB 3.5" HDDs, 4x 0.5m SAS cables | 4587EBU |
D1212 LFF Chassis, Dual 3-port ESMs, 4x 6TB 3.5" HDDs, 4x 0.5m SAS cables | 4587ECU |
D1212 LFF Chassis, Dual 3-port ESMs, 4x 8TB 3.5" HDDs, 4x 0.5m SAS cables | 4587EDU |
D1212 LFF Chassis, Dual 3-port ESMs, 8x 2TB 3.5" HDDs, 4x 0.5m SAS cables | 4587EEU |
D1212 LFF Chassis, Dual 3-port ESMs, 8x 4TB 3.5" HDDs, 4x 0.5m SAS cables | 4587EFU |
D1212 LFF Chassis, Dual 3-port ESMs, 8x 6TB 3.5" HDDs, 4x 0.5m SAS cables | 4587EGU |
D1212 LFF Chassis, Dual 3-port ESMs, 8x 8TB 3.5" HDDs, 4x 0.5m SAS cables | 4587EHU |
D1212 LFF Chassis, Dual 3-port ESMs, 12x 2TB 3.5" HDDs, 4x 0.5m SAS cables | 4587EIU |
D1212 LFF Chassis, Dual 3-port ESMs, 12x 4TB 3.5" HDDs, 4x 0.5m SAS cables | 4587EJU |
D1212 LFF Chassis, Dual 3-port ESMs, 12x 6TB 3.5" HDDs, 4x 0.5m SAS cables | 4587EKU |
D1212 LFF Chassis, Dual 3-port ESMs, 12x 8TB 3.5" HDDs, 4x 0.5m SAS cables | 4587ELU |
SFF models - North America (NA) and Europe, Middle East, and Africa (EMEA) | |
Lenovo Storage D1224 SFF Dual ESM Disk Expansion Enclosure (US English documentation) | 4587E31 |
SFF models - Brazil and Latin America | |
D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 4x 0.5m SAS cables | 4587E6U |
D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables | 4587E2U |
D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables | 4587E4U |
D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 1x 0.5m SAS cable | 4587E5U |
D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables | 4587E1U |
D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables | 4587E3U |
For details about supported drives, adapters, and cables for the Lenovo Storage D1212 and D1224, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0512
The following table lists the relationship models of the 12 Gbps SAS external high density drive enclosures that are offered by Lenovo that can be used with the System x3650 M5 for storage expansion.
Description | Part number |
---|---|
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure | 641311F |
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure | 641312F |
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure | 641313F |
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure | 641314F |
The following table lists the TopSeller models of the 12 Gbps SAS external high density drive enclosures that are offered by Lenovo that can be used with the System x3650 M5 for storage expansion..
Description | Part number |
---|---|
Lenovo Storage D3284 High Density Expansion Enclosure | 6413E5F |
Lenovo Storage D3284 4TB x 42 HD Expansion Enclosure | 6413E1H |
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure | 6413E1F |
Lenovo Storage D3284 6TB x 42 HD Expansion Enclosure | 6413E2H |
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure | 6413E2F |
Lenovo Storage D3284 8TB x 42 HD Expansion Enclosure | 6413E3H |
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure | 6413E3F |
Lenovo Storage D3284 10TB x 42 HD Expansion Enclosure | 6413E4H |
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure | 6413E4F |
For details about supported drives, adapters, and cables for the Lenovo Storage D3284, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0513
External storage systems
The following table lists the external storage systems that are currently offered by Lenovo that can be used with the System x3650 M5 in IT solutions.
Description | Part number |
---|---|
Lenovo ThinkSystem DS Series Storage (SAS connectivity) | |
Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (US English documentation) | 4599A41* |
Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (Simplified Chinese documentation) | 4599A4C^ |
Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (Japanese documentation) | 4599A4J** |
Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (US English documentation) | 4599A21* |
Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (Simplified Chinese documentation) | 4599A2C^ |
Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (Japanese documentation) | 4599A2J** |
Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (US English documentation) | 4617A41* |
Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (Simplified Chinese documentation) | 4617A4C^ |
Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (Japanese documentation) | 4617A4J** |
Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (US English documentation) | 4617A21* |
Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (Simplified Chinese documentation) | 4617A2C^ |
Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (Japanese documentation) | 4617A2J** |
Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (US English documentation) | 4619A21* |
Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (Simplified Chinese documentation) | 4619A2C^ |
Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (Japanese documentation) | 4619A2J** |
Lenovo ThinkSystem DS Series Storage (iSCSI or FC connectivity) | |
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (US English documentation) | 4599A31* |
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) | 4599A3C^ |
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation) | 4599A3J** |
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (US English documentation) | 4599A11* |
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) | 4599A1C^ |
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation) | 4599A1J** |
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (US English documentation) | 4617A31* |
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) | 4617A3C^ |
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation) | 4617A3J** |
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (US English documentation) | 4617A11* |
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) | 4617A1C^ |
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation) | 4617A1J** |
Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (US English documentation) | 4619A11* |
Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) | 4619A1C^ |
Lenovo Storage S Series (SAS connectivity) | |
Lenovo Storage S2200 LFF Chassis SAS Single Controller, Rack Kit, 9x5NBD | 64112B1 |
Lenovo Storage S2200 LFF Chassis SAS Dual Controller, Rack Kit, 9x5NBD | 64112B2 |
Lenovo Storage S2200 SFF Chassis SAS Single Controller, Rack Kit, 9x5NBD | 64112B3 |
Lenovo Storage S2200 SFF Chassis SAS Dual Controller, Rack Kit, 9x5NBD | 64112B4 |
Lenovo Storage S3200 LFF Chassis SAS Single Controller, Rack Kit, 9x5NBD | 64113B1 |
Lenovo Storage S3200 LFF Chassis SAS Dual Controller, Rack Kit, 9x5NBD | 64113B2 |
Lenovo Storage S3200 SFF Chassis SAS Single Controller, Rack Kit, 9x5NBD | 64113B3 |
Lenovo Storage S3200 SFF Chassis SAS Dual Controller, Rack Kit, 9x5NBD | 64113B4 |
Lenovo Storage S Series (iSCSI or FC connectivity) | |
Lenovo Storage S2200 LFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD | 64114B1 |
Lenovo Storage S2200 LFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD | 64114B2 |
Lenovo Storage S2200 SFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD | 64114B3 |
Lenovo Storage S2200 SFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD | 64114B4 |
Lenovo Storage S3200 LFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD | 64116B1 |
Lenovo Storage S3200 LFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD | 64116B2 |
Lenovo Storage S3200 SFF Chassis FC/iSCSI Single Controller, Rack Kit, 9x5NBD | 64116B3 |
Lenovo Storage S3200 SFF Chassis FC/iSCSI Dual Controller, Rack Kit, 9x5NBD | 64116B4 |
Lenovo Storage V Series (iSCSI or FC connectivity) | |
Lenovo Storage V3700 V2 LFF Control Enclosure | 6535C1D |
Lenovo Storage V3700 V2 LFF Control Enclosure (TopSeller) | 6535EC1 |
Lenovo Storage V3700 V2 SFF Control Enclosure | 6535C2D |
Lenovo Storage V3700 V2 SFF Control Enclosure (TopSeller) | 6535EC2 |
Lenovo Storage V3700 V2 XP LFF Control Enclosure | 6535C3D |
Lenovo Storage V3700 V2 XP LFF Control Enclosure (TopSeller) | 6535EC3 |
Lenovo Storage V3700 V2 XP SFF Control Enclosure | 6535C4D |
Lenovo Storage V3700 V2 XP SFF Control Enclosure (TopSeller) | 6535EC4 |
Lenovo Storage V5030 LFF Control Enclosure 3Yr S&S | 6536C12 |
Lenovo Storage V5030 LFF Control Enclosure 5Yr S&S | 6536C32 |
Lenovo Storage V5030 SFF Control Enclosure 3Yr S&S | 6536C22 |
Lenovo Storage V5030 SFF Control Enclosure 5Yr S&S | 6536C42 |
Lenovo Storage V5030F SFF Control Enclosure 3Yr S&S | 6536B1F |
Lenovo Storage V5030F SFF Control Enclosure 5Yr S&S | 6536B2F |
IBM Storwize for Lenovo (SAS [except V7000], iSCSI or FC connectivity) | |
IBM Storwize V3500 3.5-inch Dual Control Storage Controller Unit | 6096CU2^ |
IBM Storwize V3500 2.5-inch Dual Control Storage Controller Unit | 6096CU3^ |
IBM Storwize V3700 3.5-inch Storage Controller Unit | 6099L2C |
IBM Storwize V3700 2.5-inch Storage Controller Unit | 6099S2C |
IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA | 6195C32† |
IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA, LA | 6195C3L‡ |
IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA | 6195C52† |
IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA, LA | 6195C5L‡ |
Lenovo Storage DX8200 Series (NAS or iSCSI connectivity; optional FC connectivity) | |
Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 3yr SW S&S | 5135A2x# |
Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 4yr SW S&S | 5135J2x# |
Lenovo Storage DX8200D Storage Virtualization Entry, 4TB, 5yr SW S&S | 51351Vx# |
Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 3yr SW S&S | 5135B2x# |
Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 4yr SW S&S | 5135L2x# |
Lenovo Storage DX8200D Storage Virtualization Mid, 16TB, 5yr SW S&S | 51352Vx# |
Lenovo Storage DX8200D Storage Virtualization High, 64TB, 3yr SW S&S | 5135C3x# |
Lenovo Storage DX8200D Storage Virtualization High, 64TB, 4yr SW S&S | 5135M3x# |
Lenovo Storage DX8200D Storage Virtualization High, 64TB, 5yr SW S&S | 51353Wx# |
Lenovo Storage DX8200D ServerSAN Entry, 8TB, 3yr SW S&S | 5135D2x# |
Lenovo Storage DX8200D ServerSAN Entry, 8TB, 4yr SW S&S | 5135N2x# |
Lenovo Storage DX8200D ServerSAN Entry, 8TB, 5yr SW S&S | 51354Vx# |
Lenovo Storage DX8200D ServerSAN Mid, 16TB, 3yr SW S&S | 5135F2x# |
Lenovo Storage DX8200D ServerSAN Mid, 16TB, 4yr SW S&S | 5135P2x# |
Lenovo Storage DX8200D ServerSAN Mid, 16TB, 5yr SW S&S | 51355Vx# |
Lenovo Storage DX8200D ServerSAN High, 32TB, 3yr SW S&S | 5135G3x# |
Lenovo Storage DX8200D ServerSAN High, 32TB, 4yr SW S&S | 5135Q3x# |
Lenovo Storage DX8200D ServerSAN High, 32TB, 5yr SW S&S | 51356Wx# |
Lenovo Storage DX8200N with 1x N2226 HBA (Requires a supported external drive enclosure) | 5128C1x# |
Lenovo Storage DX8200N with 2x N2226 HBAs (Requires a supported external drive enclosure) | 5128C2x# |
Lenovo Storage DX8200C Series (S3 cloud storage) | |
Lenovo Storage DX8200C 56TB (14x 4TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S | 5120C1x# |
Lenovo Storage DX8200C 84TB (14x 6TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S | 5120C3x# |
Lenovo Storage DX8200C 112TB (14x 8TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S | 5120C2x# |
Lenovo Storage DX8200C 140TB (14x 10TB HDDs) with Cloudian HyperStore - 3yr HW/SW S&S | 5120C4x# |
* Available worldwide (except China and Japan).
^ Available only in China.
** Available only in Japan.
† Available worldwide except Latin America.
‡ Available only in Latin America.
# x represents a geo-specific letter (for example: U = North America, G = EMEA). Ask a Lenovo representative for specifics.
For more information, see the list of Product Guides in the following categories:
- Lenovo DS Series, S Series, and V Series storage:
http://lenovopress.com/storage/san/lenovo#rt=product-guide - IBM Storwize for Lenovo storage:
http://lenovopress.com/storage/san/ibm#rt=product-guide - Lenovo Cloud storage:
http://lenovopress.com/storage/cloud#rt=product-guide - Lenovo NAS storage:
http://lenovopress.com/storage/nas#rt=product-guide
External backup units
The following table lists the external backup options that are offered by Lenovo that can be used with the System x3650 M5 in backup solutions.
Description | Part number |
External RDX USB drives | |
RDX External USB 3.0 Dock with 320GB Cartridge | 362532Y |
RDX External USB 3.0 Dock with 500GB Cartridge | 362550Y |
RDX External USB 3.0 Dock with 1TB Cartridge | 36251TY |
External SAS tape backup drives | |
IBM TS2250 Tape Drive Model H5S | 6160S5E |
IBM TS2260 Tape Drive Model H6S | 6160S6E |
IBM TS2270 Tape Drive Model H7S | 6160S7E |
External SAS tape backup autoloaders | |
IBM TS2900 Tape Autoloader w/LTO5 HH SAS | 6171S5R |
IBM TS2900 Tape Autoloader w/LTO6 HH SAS | 6171S6R |
IBM TS2900 Tape Autoloader w/LTO7 HH SAS | 6171S7R |
External tape backup libraries | |
IBM TS3100 Tape Library Model L2U | 61732UL |
IBM TS3200 Tape Library Model L4U | 61734UL |
Fibre Channel backup drives for TS3100 and TS3200 Tape Libraries | |
6173 LTO Ultrium 5 Fibre Channel Drive | 00NA107 |
6173 LTO Ultrium 5 Half High Fibre Drive Sled | 00NA113 |
6173 LTO Ultrium 6 Fibre Channel Drive | 00NA115 |
6173 LTO Ultrium 6 Half High Fibre Drive Sled | 00NA119 |
6173 LTO Ultrium 7 Fibre Channel Drive | 00WF765 |
6173 LTO Ultrium 7 Half High Fibre Drive Sled | 00WF769 |
SAS backup drives for TS3100 and TS3200 Tape Libraries | |
6173 LTO Ultrium 5 SAS Drive Sled | 00NA109 |
6173 LTO Ultrium 5 Half High SAS Drive Sled | 00NA111 |
6173 LTO Ultrium 6 Half High SAS Drive Sled | 00NA117 |
6173 LTO Ultrium 7 Half High SAS Drive Sled | 00WF767 |
For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup
Ethernet LAN switches
The following table lists the Ethernet LAN switches that are offered by Lenovo that can be used with the System x3650 M5 server in IT solutions.
Description | Part number |
---|---|
1 Gb Ethernet switches | |
Juniper EX2300-C PoE Switch | 7165H1X |
Juniper EX2300-24p PoE Switch | 7165H2X |
Lenovo RackSwitch G7028 (Rear to Front) | 7159BAX |
Lenovo RackSwitch G7052 (Rear to Front) | 7159CAX |
Lenovo RackSwitch G8052 (Rear to Front) | 7159G52 |
10 Gb Ethernet switches | |
Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front) | 7159A1X |
Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front) | 7159B1X |
Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front) | 7159C1X |
Lenovo RackSwitch G8124E (Rear to Front) | 7159BR6 |
Lenovo RackSwitch G8264 (Rear to Front) | 7159G64 |
Lenovo RackSwitch G8264CS (Rear to Front) | 7159DRX |
Lenovo RackSwitch G8272 (Rear to Front) | 7159CRW |
Lenovo RackSwitch G8296 (Rear to Front) | 7159GR6 |
25 Gb Ethernet switches | |
Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front) | 7159E1X |
40 Gb Ethernet switches | |
Lenovo RackSwitch G8332 (Rear to Front) | 7159BRX |
100 Gb Ethernet switches | |
Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front) | 7159D1X |
For more information, see the list of Product Guides in the Top-of-rack Switches category:
http://lenovopress.com/servers/options/switches#rt=product-guide
Fibre Channel SAN switches
The following table lists currently available Fibre Channel SAN switches that are offered by Lenovo that can be used with the System x3650 M5 in IT solutions.
Description | Part number |
---|---|
8 Gb FC | |
Lenovo B300, 8 ports activated, 8x 8Gb SWL SFPs, 1 PS, Rail Kit | 3873AR3 |
Lenovo B6505, 12 ports activated, 12x 8Gb SWL SFPs, 1 PS, Rail Kit | 3873AR4 |
Lenovo B6510, 24 ports activated, 24x 8Gb SWL SFPs, 2 PS, Rail Kit | 3873BR2 |
16 Gb FC | |
Lenovo ThinkSystem DB610S, 8 ports activated, 8x 16Gb SWL SFPs, 1 PS, Rail Kit | 6559D2Y |
Lenovo ThinkSystem DB610S, 24 ports activated, 24x 16Gb SWL SFP, Enterprise SW, 1 PS, Rail Kit | 6559D1Y |
Lenovo B6505, 12 ports activated w/ 16Gb SWL SFPs, 1 PS, Rail Kit | 3873AR5 |
Lenovo B6510, 24 ports activated w/ 16Gb SWL SFPs, 2 PS, Rail Kit | 3873BR3 |
32 Gb FC | |
Lenovo ThinkSystem DB610S, 8 ports activated, 1 PS, Rail Kit | 6559D3Y |
Lenovo ThinkSystem DB620S, 24 Ports Activated, 24x 32Gb SWL SFPs, 2 PS, Rail Kit | 6415G11 |
Lenovo ThinkSystem DB620S, 48 Ports Activated, 48x 32Gb SWL SFPs, 2 PS, Rail Kit | 6415G2A |
Lenovo ThinkSystem DB400D 32Gb FC Director, up to 192 ports, 8U, Enterprise SW | 6684B2A |
Lenovo ThinkSystem DB800D 32Gb FC Director, up to 384 ports, 14U, Enterprise SW | 6682B1A |
For more information, see the list of Product Guides in the Rack SAN Switches category:
http://lenovopress.com/storage/switches/rack#rt=product-guide
Rack cabinets
The following table lists the rack cabinets that are offered by Lenovo that can be used in System x3550 M5 solutions.
Description | Part number |
---|---|
25U S2 Standard Rack (1000 mm deep; 2 sidewall compartments) | 93072RX |
25U Static S2 Standard Rack (1000 mm deep; 2 sidewall compartments) | 93072PX |
42U S2 Standard Rack (1000 mm deep; 6 sidewall compartments) | 93074RX |
42U 1100mm Enterprise V2 Dynamic Rack (6 sidewall compartments) | 93634PX |
42U 1100mm Enterprise V2 Dynamic Expansion Rack (6 sidewall compartments) | 93634EX |
42U 1200mm Deep Dynamic Rack (6 sidewall compartments) | 93604PX |
42U 1200mm Deep Static Rack (6 sidewall compartments) | 93614PX |
42U Enterprise Rack (1105 mm deep; 4 sidewall compartments) | 93084PX |
42U Enterprise Expansion Rack (1105 mm deep; 4 sidewall compartments) | 93084EX |
For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks
KVM switches and consoles
The following table lists the KVM switches and consoles that are offered by Lenovo that can be used in System x3650 M5 solutions.
Description | Part number |
Consoles | |
1U 18.5" Standard Console (without keyboard) | 17238BX |
Console keyboards | |
Lenovo UltraNav Keyboard USB - US Eng | 00MW310 |
Keyboard w/ Int. Pointing Device USB - Arabic 253 RoHS v2 | 46W6713 |
Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2 | 46W6714 |
Keyboard w/ Int. Pointing Device USB - Chinese/US 467 RoHS v2 | 46W6715 |
Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2 | 46W6716 |
Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2 | 46W6717 |
Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2 | 46W6718 |
Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2 | 46W6719 |
Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2 | 46W6720 |
Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2 | 46W6721 |
Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2 | 46W6722 |
Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2 | 46W6723 |
Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2 | 46W6724 |
Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2 | 46W6725 |
Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2 | 46W6726 |
Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2 | 46W6727 |
Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2 | 46W6728 |
Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2 | 46W6729 |
Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2 | 46W6730 |
Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2 | 46W6731 |
Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2 | 46W6732 |
Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2 | 46W6733 |
Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2 | 46W6734 |
Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2 | 46W6735 |
Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2 | 46W6736 |
Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2 | 46W6737 |
Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2 | 46W6738 |
Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2 | 46W6739 |
Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2 | 46W6740 |
Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2 | 46W6741 |
Console switches | |
Global 4x2x32 Console Manager (GCM32) | 1754D2X |
Global 2x2x16 Console Manager (GCM16) | 1754D1X |
Local 2x16 Console Manager (LCM16) | 1754A2X |
Local 1x8 Console Manager (LCM8) | 1754A1X |
Console cables | |
Single Cable USB Conversion Option (UCO) | 43V6147 |
USB Conversion Option (4 Pack UCO) | 39M2895 |
Virtual Media Conversion Option Gen2 (VCO2) | 46M5383 |
Serial Conversion Option (SCO) | 46M5382 |
For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm
Uninterruptible power supply units
The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in System x3650 M5 solutions.
Description | Part number |
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) | 55941AX |
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) | 55941KX |
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) | 55942AX |
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) | 55942KX |
RT3kVA 2U Rack or Tower UPS (100-125VAC) | 55943AX |
RT3kVA 2U Rack or Tower UPS (200-240VAC) | 55943KX |
RT5kVA 3U Rack or Tower UPS (200-240VAC) | 55945KX |
RT6kVA 3U Rack or Tower UPS (200-240VAC) | 55946KX |
RT8kVA 6U Rack or Tower UPS (200-240VAC) | 55948KX |
RT11kVA 6U Rack or Tower UPS (200-240VAC) | 55949KX |
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) | 55948PX |
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) | 55949PX |
For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups
Power distribution units
The following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used in System x3650 M5 solutions.
Description | Part number |
---|---|
0U Basic PDUs | |
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord | 00YJ776 |
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord | 00YJ777 |
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord | 00YJ778 |
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord | 00YJ779 |
Switched and Monitored PDUs | |
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord | 00YJ781 |
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord | 00YJ780 |
0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord | 00YJ782 |
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord | 00YJ783 |
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord) | 46M4002 |
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord | 46M4003 |
1U 12 C13 Switched and Monitored DPI PDU (without line cord) | 46M4004 |
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord | 46M4005 |
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets) | |
Ultra Density Enterprise C19/C13 PDU Module (without line cord) | 71762NX |
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord | 71763NU |
C13 Enterprise PDUs (12x IEC 320 C13 outlets) | |
DPI C13 Enterprise PDU+ (without line cord) | 39M2816 |
DPI Single Phase C13 Enterprise PDU (without line cord) | 39Y8941 |
C19 Enterprise PDUs (6x IEC 320 C19 outlets) | |
DPI Single Phase C19 Enterprise PDU (without line cord) | 39Y8948 |
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord | 39Y8923 |
Front-end PDUs (3x IEC 320 C19 outlets) | |
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord | 39Y8938 |
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord | 39Y8939 |
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8934 |
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8940 |
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord | 39Y8935 |
Universal PDUs (7x IEC 320 C13 outlets) | |
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord) | 00YE443 |
NEMA PDUs (6x NEMA 5-15R outlets) | |
DPI 100-127V PDU with fixed NEMA L5-15P line cord | 39Y8905 |
Line cords for PDUs that ship without a line cord | |
DPI 30a Line Cord (NEMA L6-30P) | 40K9614 |
DPI 32a Line Cord (IEC 309 P+N+G) | 40K9612 |
DPI 32a Line Cord (IEC 309 3P+N+G) | 40K9611 |
DPI 60a Cord (IEC 309 2P+G) | 40K9615 |
DPI 63a Cord (IEC 309 P+N+G) | 40K9613 |
DPI Australian/NZ 3112 Line Cord (32A) | 40K9617 |
DPI Korean 8305 Line Cord (30A) | 40K9618 |
For more information, see the list of Product Guides in the PDU category:
https://lenovopress.com/servers/options/pdu
Lenovo Financial Services
Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.
We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.
We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.
We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.
Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.
For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:
http://www.lenovofs.com
Related product families
Product families related to this document are the following:
- 2-Socket Rack Servers
”THẾ GIỚI SỐ – NHÀ CUNG CẤP DỊCH VỤ HOSTING, VPS, CLOUD, SERVER CHUYÊN NGHIỆP TẠI VIỆT NAM”